Cognex In-Sight 2000 series
Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Default Permissions
A local attacker with low privileges on the Windows system where the software is installed can exploit this vulnerability to corrupt sensitive data. A data folder is created with very weak privileges, allowing any user logged into the Windows system to modify its content.
Affected versions and mitigation
From the CVE record and the vendor's references.Affected
- >= 5.x, <= 6.5.1
- >= 5.x, <= 6.5.1
- >= 5.x, <= 6.5.1
- >= 5.x, <= 6.5.1
- >= 5.x, <= 6.5.1
Mitigation
The record names no fix. Check the vendor advisory below.
Workaround
Cognex reports that In-Sight Explorer based vision systems are legacy products not intended for new applications. To reduce risk, asset owners are advised to switch to next generation In-Sight Vision Suite based vision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 series embedded cameras.
Timeline
Days relative to CVE publicationNo public PoC found yet; not in CISA KEV.
PoC repositories
Found on GitHub.No PoC repositories found yet.