  "id": "CVE-2025-53947",
  "url": "https://poc.griffinguard.io/cve/CVE-2025-53947",
  "published_at": "2025-09-18T21:10:03.344Z",
  "title": "Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Default Permissions",
  "vendor": "Cognex",
  "product": "In-Sight 2000 series",
  "cvss": {
    "score": 7.7,
    "source": "cna",
    "vector": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": null,
  "description": "A local attacker with low privileges on the Windows system where the \nsoftware is installed can exploit this vulnerability to corrupt \nsensitive data. A data folder is created with very weak privileges, \nallowing any user logged into the Windows system to modify its content.",
  "cwe": "CWE-276",
  "cvss_by_source": {
    "cna": 7.7
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "Cognex",
        "product": "In-Sight 2000 series",
        "ranges": [
          "\u003e= 5.x, \u003c= 6.5.1"
        ],
        "fixed_in": null
      },
      {
        "vendor": "Cognex",
        "product": "In-Sight 7000 series",
        "ranges": [
          "\u003e= 5.x, \u003c= 6.5.1"
        ],
        "fixed_in": null
      },
      {
        "vendor": "Cognex",
        "product": "In-Sight 8000 series",
        "ranges": [
          "\u003e= 5.x, \u003c= 6.5.1"
        ],
        "fixed_in": null
      },
      {
        "vendor": "Cognex",
        "product": "In-Sight 9000 series",
        "ranges": [
          "\u003e= 5.x, \u003c= 6.5.1"
        ],
        "fixed_in": null
      },
      {
        "vendor": "Cognex",
        "product": "In-Sight Explorer",
        "ranges": [
          "\u003e= 5.x, \u003c= 6.5.1"
        ],
        "fixed_in": null
      }
    ],
    "workarounds": [
      "Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras."
    ]
  },
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}