FastNetMon
FastNetMon: NetFlow v9 unbounded strlen() on interface-description field causes remote out-of-bounds read
FastNetMon is a high-performance DDoS detector and sensor. In version 1.2.9 and earlier, the NetFlow v9 collector calls strlen() on an attacker-controlled interface-description field without bounding the scan to the field’s declared length. Although fields longer than 128 bytes are excluded from this operation, an accepted field without a null terminator can cause reads beyond the field and packet buffer. An unauthenticated remote attacker who can send crafted UDP packets to the collector can trigger an out-of-bounds read and potentially crash the process, causing denial of service. No fixed release is available as of this review.
Affected versions and mitigation
From the CVE record and the vendor's references.Affected
- <= 1.2.9
Mitigation
The record names no fix. Check the vendor advisory below.
References
Timeline
Days relative to CVE publicationNo public PoC found yet; not in CISA KEV.
PoC repositories
Found on GitHub.No PoC repositories found yet.