Arista Networks VeloCloud Edge
Security Advisory 0179
An unauthenticated actor with network access to the private HA interconnect may trigger sensitive HA peer functions without verification. This could result in elevated command execution on Edge units where HA is enabled.
Affected versions and mitigation
From the CVE record and the vendor's references.Affected
- >= 1.0.0.0, < 5.2.0.0
- >= 5.2.0.0, < 5.2.7.0
- >= 6.1.0.0, < 6.1.5.0
- >= 6.4.0.0, < 6.4.2.0
Fixed in 5.2.0.0, 5.2.7.0, 6.1.5.0, 6.4.2.0
Mitigation
The following VeloCloud Edge releases contain the fix: - 5.2.7.0 and later in the 5.2.x train - 6.1.5.0 and later in the 6.1.x train - 6.4.2 and later in the 6.4.x train - 7.0.0 and later No hotfixes are available for this issue.
Workaround
Use dedicated port-to-port connections between HA pairs. Avoid extending the HA interconnect through shared switches or VLANs. Restrict physical and network access to HA interfaces.
References
- Vendor advisory arista.com/en/support/advisories-notices/secur…
Timeline
Days relative to CVE publicationNo public PoC found yet; not in CISA KEV.
PoC repositories