WolfVision Cynap Pure (Next Gen), Cynap Bridge
Unauthenticated RCE Vulnerability in WolfProt interface implementation
A security vulnerability has been identified in the WolfProt interface implementation. Insufficient neutralization of user-controlled input could allow an unauthenticated attacker with network access to a vulnerable service to execute operating-system commands with the privileges of the affected application service.
Affected versions and mitigation
From the CVE record and the vendor's references.Affected
- < 2.00c
Fixed in 2.00c
- < 1.78a
Fixed in 1.78a
- < 1.72e
Fixed in 1.72e
- 0
Mitigation
Upgrade Cynap Pure (Next Gen), Cynap Bridge to 2.00c or later.
Upgrade Cynap Pro, Cynap Core Pro, Cynap Receiver, Cynap Pure, Cynap Pure Mini, Cynap Pure Pro to 1.78a or later.
Upgrade Cynap Videobar, Firmware Version to 1.72e or later.
Workaround
Until an update can be applied, restrict network access to the WolfProt-related ports (TCP 50915 and 50917) as well as the web management interfaces (TCP 80 and 443) to trusted hosts only. Note that these services cannot be disabled. WolfVision recommends keeping devices up to date and using dedicated, managed network segments (VLAN or firewall zone) to restrict device access to trusted hosts only.
References
- Vendor advisory wolfvision.com/de/security/cve-2026-59106-2
Timeline
Days relative to CVE publicationNo public PoC found yet; not in CISA KEV.
PoC repositories
Found on GitHub.No PoC repositories found yet.