PoC Monitor
← All CVEs
CVE-2026-58115published 11 Aug 2026 12:20 UTCData: JSON · API

Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2)

A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions running Example Image versions with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server. This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges.

First public PoC 85 daysafter publication · 4 Nov 2026
Public PoCs11 on GitHub
CVSS10.0critical · scored by CNA · CWE-306
CISA KEV Not listednot known exploited

Affected versions and mitigation

From the CVE record and the vendor's references.

Affected

Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2)
  • < V4.3.4-1

Fixed in V4.3.4-1

Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2)
  • < *

Fixed in *

Siemens SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2)
  • < V4.3.4-1

Fixed in V4.3.4-1

Siemens SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2)
  • < *

Fixed in *

Siemens SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2)
  • < V4.3.4-1

Fixed in V4.3.4-1

Siemens SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2)
  • < *

Fixed in *

Siemens SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2)
  • < V4.3.4-1

Fixed in V4.3.4-1

Siemens SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2)
  • < *

Fixed in *

Mitigation

Upgrade SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) to V4.3.4-1 or later.

Upgrade SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) to * or later.

Upgrade SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) to V4.3.4-1 or later.

Upgrade SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) to * or later.

Upgrade SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) to V4.3.4-1 or later.

Upgrade SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) to * or later.

Upgrade SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) to V4.3.4-1 or later.

Upgrade SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) to * or later.

Timeline

Days relative to CVE publication
t=0+14+28+42+56+70+84CVE published11 Aug 2026 · t = 0First public PoC4 Nov 2026 · t+85d

First public PoC 85 days after publication; not in CISA KEV. First PoC: al4n4n/CVE-2026-58115 (created 4 Nov 2026, found by us: 14 Nov 2026).

PoC repositories

Found on GitHub.

1 PoCs · 1 pending

PoCs 1
RepositoryCreatedFound by usStarsAssessment
al4n4n/CVE-2026-58115 4 Nov 2026 +85 d 14 Nov 2026 1 PoC
Pending 1
RepositoryCreatedFound by usStarsAssessment
foxcornlab/node-red-scanner 3 Nov 2026 +84 d 14 Nov 2026 2 Pending

Only PoCs count toward the first-PoC date and the characteristics below. Do not run PoC code from unknown sources.

PoC characteristics

What to hunt for in your logs · from 1 PoC repo

Regex

Generated from PoC characteristics; not yet reviewed. Matches the request path and query.

GET /auth/login
(?i)^/auth/login(?:[?#].*)?$
GET /settings
(?i)^/settings(?:[?#].*)?$

Suricata

Template generated from PoC characteristics. Review before deploying.

GET /auth/login
alert http any any -> $HOME_NET [1880] (msg:"GG PoC-Monitor CVE-2026-58115 Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) exploit attempt"; flow:established,to_server; http.method; content:"GET"; http.uri; content:"/auth/login"; reference:url,poc.griffinguard.io/cve/CVE-2026-58115; classtype:web-application-attack; sid:9126862; rev:1;)
GET /settings
alert http any any -> $HOME_NET [1880,1882] (msg:"GG PoC-Monitor CVE-2026-58115 Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) exploit attempt"; flow:established,to_server; http.method; content:"GET"; http.uri; content:"/settings"; reference:url,poc.griffinguard.io/cve/CVE-2026-58115; classtype:web-application-attack; sid:9159779; rev:1;)

Sigma

Template generated from PoC characteristics. Review before deploying.

GET /auth/login
title: Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) exploit attempt (CVE-2026-58115)
id: gg-pocmon-cve-2026-58115-9126862
status: experimental
description: Request pattern taken from public PoCs for CVE-2026-58115. Generated, not reviewed.
references:
  - https://poc.griffinguard.io/cve/CVE-2026-58115
logsource:
  category: webserver
detection:
  selection:
    cs-method: GET
    cs-uri-stem|contains|all:
      - '/auth/login'
  condition: selection
falsepositives:
  - Authorized vulnerability scanning
level: critical
tags:
  - attack.initial_access
  - attack.t1190
  - cve.2026.58115
GET /settings
title: Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) exploit attempt (CVE-2026-58115)
id: gg-pocmon-cve-2026-58115-9159779
status: experimental
description: Request pattern taken from public PoCs for CVE-2026-58115. Generated, not reviewed.
references:
  - https://poc.griffinguard.io/cve/CVE-2026-58115
logsource:
  category: webserver
detection:
  selection:
    cs-method: GET
    cs-uri-stem|contains|all:
      - '/settings'
  condition: selection
falsepositives:
  - Authorized vulnerability scanning
level: critical
tags:
  - attack.initial_access
  - attack.t1190
  - cve.2026.58115