PoC Monitor
← All CVEs
CVE-2026-58114published 10 Nov 2026 11:30 UTCData: JSON · API

Siemens SIMATIC BATCH V9.1

A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions), SIMATIC Information Server 2022 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Process Historian 2020 (All versions), SIMATIC Process Historian 2022 (All versions), SIMATIC WinCC Runtime Professional V17 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions), SIMATIC WinCC Runtime Professional V20 (All versions), SIMATIC WinCC Runtime Professional V21 (All versions), SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions), SIMATIC WinCC V8.1 (All versions). Affected systems do not properly secure their remote user authentication with the deprecated NTLM protocol. This could allow unauthenticated remote attackers, who have achieved a machine in the middle position, to relay NTLM authentication and impersonate a legitimate user. The potential impact depends on the services that are accessible, e.g. a SQL server used by WinCC.

First public PoC None yetno public PoC found
Public PoCs00 on GitHub
CVSS7.7high · scored by CNA · CWE-1390
CISA KEV Not listednot known exploited

Affected versions and mitigation

From the CVE record and the vendor's references.

Affected

Siemens SIMATIC BATCH V9.1
  • < *

Fixed in *

Siemens SIMATIC Information Server 2020
  • < *

Fixed in *

Siemens SIMATIC Information Server 2022
  • < *

Fixed in *

Siemens SIMATIC PCS 7 V9.1
  • < *

Fixed in *

Siemens SIMATIC Process Historian 2020
  • < *

Fixed in *

Siemens SIMATIC Process Historian 2022
  • < *

Fixed in *

Siemens SIMATIC WinCC Runtime Professional V17
  • < *

Fixed in *

Siemens SIMATIC WinCC Runtime Professional V18
  • < *

Fixed in *

Siemens SIMATIC WinCC Runtime Professional V19
  • < *

Fixed in *

Siemens SIMATIC WinCC Runtime Professional V20
  • < *

Fixed in *

Siemens SIMATIC WinCC Runtime Professional V21
  • < *

Fixed in *

Siemens SIMATIC WinCC V7.5
  • < *

Fixed in *

Siemens SIMATIC WinCC V8.0
  • < *

Fixed in *

Siemens SIMATIC WinCC V8.1
  • < *

Fixed in *

Mitigation

Upgrade SIMATIC BATCH V9.1 to * or later.

Upgrade SIMATIC Information Server 2020 to * or later.

Upgrade SIMATIC Information Server 2022 to * or later.

Upgrade SIMATIC PCS 7 V9.1 to * or later.

Upgrade SIMATIC Process Historian 2020 to * or later.

Upgrade SIMATIC Process Historian 2022 to * or later.

Upgrade SIMATIC WinCC Runtime Professional V17 to * or later.

Upgrade SIMATIC WinCC Runtime Professional V18 to * or later.

Upgrade SIMATIC WinCC Runtime Professional V19 to * or later.

Upgrade SIMATIC WinCC Runtime Professional V20 to * or later.

Upgrade SIMATIC WinCC Runtime Professional V21 to * or later.

Upgrade SIMATIC WinCC V7.5 to * or later.

Upgrade SIMATIC WinCC V8.0 to * or later.

Upgrade SIMATIC WinCC V8.1 to * or later.

Timeline

Days relative to CVE publication
-2t=0+2+4+6+8CVE published10 Nov 2026 · t = 0

No public PoC found yet; not in CISA KEV.

PoC repositories

Found on GitHub.

No PoC repositories found yet.