Tenda i12
Tenda i12 Parameter wifiSSIDset formwrlSSIDset stack-based overflow
Edge device · Router / network deviceknown edge product: Tenda i12 Tenda i12 Parameter wifiSSIDset formwrlSSIDset (high confidence)
A flaw has been found in Tenda i12 1.0.0.11(3862). Affected by this vulnerability is the function formwrlSSIDset of the file /goform/wifiSSIDset of the component Parameter Handler. This manipulation of the argument index/wl_radio causes stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used.
First public PoC
None yetno public PoC found
Public PoCs00 on GitHub
CVSS9.0critical · scored by CNA · CWE-121
CISA KEV
Not listednot known exploited
Affected versions and mitigation
From the CVE record and the vendor's references.Affected
Tenda i12
- 1.0.0.11(3862)
Mitigation
The record names no fix. Check the vendor advisory below.
Timeline
Days relative to CVE publicationNo public PoC found yet; not in CISA KEV.
PoC repositories
Found on GitHub.No PoC repositories found yet.
Other public exploits
Exploit-DB, Metasploit and nuclei count as public PoCs. Exploit-tagged references from the CVE record and NVD are links only. None of these are analysed by us.| Source | Title | Published | Found by us |
|---|---|---|---|
| PoC Index | https://github.com/Litengzheng/vuldb_new/blob/main/i12/vul_107/README.md | unknown | 14 Nov 2026 |