Paessler GmbH PRTG Network Monitor
Plaintext Password Disclosure via VBScript Sensor Error Message in Paessler PRTG Network Monitor
PRTG Network Monitor before version 26.2.120.1449 ships a demo EXE/Script sensor that multiplies two integer parameters using cscript.exe. If a non-numeric value is passed instead, cscript.exe raises a 'Type mismatch' runtime error that includes the offending parameter value in plaintext. PRTG provides a documented placeholder variable, %windowspassword, which resolves to the configured Windows/domain password used by PRTG and can be passed as a sensor parameter. Any PRTG user who is not restricted to read-only access and is permitted to create sensors (the default for non-read-only users) can pass %windowspassword as an argument to the demo VBScript sensor, triggering the type-mismatch error and causing PRTG to display the plaintext password in the sensor's error output.
Affected versions and mitigation
From the CVE record and the vendor's references.Affected
- < 26.2.120.1449
Fixed in 26.2.120.1449
Mitigation
Upgrade to Paessler PRTG Network Monitor version 26.2.120.1449 or later.
References
- Vendor advisory paessler.freshdesk.com/en/support/solutions/articles/76000…
- Patch paessler.com/de/download
Timeline
Days relative to CVE publicationNo public PoC found yet; not in CISA KEV.
PoC repositories
Found on GitHub.No PoC repositories found yet.