Red Lion Controls 700 Series
Red Lion Controls N-Tron 700 Series Insufficiently Protected Credentials
Usernames and passwords, including the default factory credentials, are stored in plaintext within the configuration file. With administrator rights, the configuration file can be viewed through the CLI or they can be exported from the device through a TFTP transfer from the web interface. A TFTP transfer can be initiated through SNMP which does not require authentication.
Affected versions and mitigation
From the CVE record and the vendor's references.Affected
- < Firmware Versions 3.11.0
- < Bootloader Versions 2.0.6.1
Fixed in Firmware Versions 3.11.0, Bootloader Versions 2.0.6.1, 3.11.1
Mitigation
Red Lion controls recommends the following upgrades for the N-Tron 700 Series: * Upgrade to firmware version 3.11.1 or greater * Configure or disable the SNMP communities * Disable access to the web GUI The upgrade procedure document can be viewed here https://www.hms-networks.com/ . The advisory issued by HMS Networks regarding these vulnerabilities can be viewed here https://www.hms-networks.com/cybersecurity .
Timeline
Days relative to CVE publicationNo public PoC found yet; not in CISA KEV.
PoC repositories
Found on GitHub.No PoC repositories found yet.