OpenEMR
OpenEMR: Inverted ACL Condition in CDR ControllerRouter Allows Any Authenticated User to Modify/Delete Clinical Rules and Plans
OpenEMR is a free and open source electronic health records and medical practice management application. Prior to 8.0.0.1, an inverted boolean condition in ControllerRouter::route() causes the admin/super ACL check to be enforced only for controllers that already have their own internal authorization (review, log), while leaving all other CDR controllers — alerts, ajax, edit, add, detail, browse — accessible to any authenticated user. This allows any logged-in user to suppress clinical decision support alerts system-wide, delete or modify clinical plans, and edit rule configurations — all operations intended to require administrator privileges. This vulnerability is fixed in 8.0.0.1.
Affected versions and mitigation
From the CVE record and the vendor's references.Affected
- < 8.0.0.1
Fixed in 8.0.0.1
Mitigation
Upgrade openemr to 8.0.0.1 or later.
References
- Vendor advisory github.com/openemr/openemr/security/advisories…
Timeline
Days relative to CVE publicationNo public PoC found yet; not in CISA KEV.
PoC repositories
Found on GitHub.No PoC repositories found yet.