Red Lion Controls 700 Series
Red Lion Controls N-Tron 700 Series Download of Code Without Integrity Check
No authentication is required when updating firmware or bootloader, making it easy for malicious files to be pushed to the device. Additionally, anyone with the same software can scan a network for N-Tron devices and push/pull firmware without authenticating by using SNMP/TFTP.
Affected versions and mitigation
From the CVE record and the vendor's references.Affected
- < Firmware Versions 3.11.0
- < Bootloader Versions 2.0.6.1
Fixed in Firmware Versions 3.11.0, Bootloader Versions 2.0.6.1, 3.11.1
Mitigation
Red Lion controls recommends the following upgrades for the N-Tron 700 Series: * Upgrade to firmware version 3.11.1 or greater * Configure or disable the SNMP communities * Disable access to the web GUI The upgrade procedure document can be viewed here https://www.hms-networks.com/ . The advisory issued by HMS Networks regarding these vulnerabilities can be viewed here https://www.hms-networks.com/cybersecurity .