Calero VeraSMART
Calero VeraSMART < 2022 R1 Static IIS Machine Keys Enable ViewState RCE
Calero VeraSMART versions prior to 2022 R1 use static ASP.NET/IIS machineKey values configured for the VeraSMART web application and stored in C:\\Program Files (x86)\\Veramark\\VeraSMART\\WebRoot\\web.config. An attacker who obtains these keys can craft a valid ASP.NET ViewState payload that passes integrity validation and is accepted by the application, resulting in server-side deserialization and remote code execution in the context of the IIS application.
Affected versions and mitigation
From the CVE record and the vendor's references.Affected
- < 2022 R1
Fixed in 2022 R1
Mitigation
Upgrade VeraSMART to 2022 R1 or later.
Timeline
Days relative to CVE publicationFirst public PoC 75 days after publication; not in CISA KEV. First PoC: Repetier-Server 1.4.10 - Path Traversal (Exploit-DB, 30 Apr 2026).
PoC repositories
Found on GitHub.1 suspicious or fake
Suspicious or fake 1
| Repository | Created | Stars | Assessment |
|---|---|---|---|
| mbanyamer/CVE-2026-26335-Calero-VeraSMART-RCE | 14 Feb 2026 +11 h | 0 | Fake |
Only PoCs count toward the first-PoC date and the characteristics below. Do not run PoC code from unknown sources.
Other public exploits
Exploit-DB, Metasploit and nuclei count as public PoCs. Exploit-tagged references from the CVE record and NVD are links only. None of these are analysed by us.| Source | Title | Published | Found by us |
|---|---|---|---|
| Exploit-DB | Repetier-Server 1.4.10 - Path Traversal | 30 Apr 2026 | 14 Nov 2026 |