IBM Power Systems Firmware
Power System Buffer Overflow
Edge device · Device firmwarehardware or firmware CPE: ibm power_system_e1050_\(9043-mrx\)_firmware (medium confidence)
Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the host firmware boot process image validation path. An attacker with service access to the service processor can supply a maliciously crafted code update image, allowing arbitrary code to be executed on the host system. Successful exploitation could result in a confidentiality, integrity, and availability impact to the affected host system.
Affected versions and mitigation
From the CVE record and the vendor's references.Affected
- FW1120.00
- >= FW1110.00, <= FW1110.30
- >= FW1060.00, <= FW1060.80
Mitigation
Customers with the products below should install FW1110.31(1110_134), FW1120.01(1120_167), or newer to remediate this vulnerability. Power 11 IBM Power System E1180 (9080-HEU) Customers with the products below should install FW1110.31(1110_155), FW1120.01(1120_190), or newer to remediate this vulnerability. Power 11 IBM Power System S1122 (9824-22A) IBM Power System S1124 (9824-42A) IBM Power System S1122s (9824-22B) IBM Power System S1114 (9824-41B) IBM Power System L1122 (9856-22H) IBM Power System L1124 (9856-42H) IBM Power System E1150 (9043-MRU) Customers with the products below should install FW1120.01(1120_190), or newer to remediate this vulnerability. Power 11 IBM Power System S1112 (9242-21B, 9242-21T) Customers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability. Power 10 IBM Power System E1080 (9080-HEX) Customers with the products below should install FW1060.81(1060_191), or newer to remediate this vulnerability. Power 10 IBM Power System S1022 (9105-22A) IBM Power System S1024 (9105-42A) IBM Power System S1022s (9105-22B) IBM Power System S1014 (9105-41B) IBM Power System L1022 (9786-22H) IBM Power System L1024 (9786-42H) IBM Power System E1050 (9043-MRX) IBM Power System S1012 (9028-21B) The images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/
References
- Vendor advisory ibm.com/support/pages/node/7283221
Timeline
Days relative to CVE publicationNo public PoC found yet; not in CISA KEV.
PoC repositories
Found on GitHub.No PoC repositories found yet.