PoC Monitor
← All CVEs
CVE-2026-127124published 13 Nov 2026 13:25 UTCData: JSON · API

RT-Labs P-Net

RPC session pool exhausted by unfinished fragmented requests

P-Net before 1.0.4 keeps the RPC session that is allocated for a fragment of a request with an unknown activity UUID, without a timeout, when the rest of the request never arrives. A session that does not get an Application Relationship is also kept after the response. Repeated fragments or requests with different activity UUIDs exhaust the available sessions, one UDP packet per session. Once they are exhausted the device no longer answers a Connect request until it is restarted. An unauthenticated attacker with ADJACENT network access can use this to cause a denial of service.

First public PoC None yetno public PoC found
Public PoCs00 on GitHub
CVSS7.1high · scored by CNA · CWE-772
CISA KEV Not listednot known exploited

Affected versions and mitigation

From the CVE record and the vendor's references.

Affected

RT-Labs P-Net
  • < 1.0.4

Fixed in 1.0.4

Mitigation

Upgrade to P-Net 1.0.4 or later.

Timeline

Days relative to CVE publication
-2t=0+2+4+6+8CVE published13 Nov 2026 · t = 0

No public PoC found yet; not in CISA KEV.

PoC repositories

Found on GitHub.

No PoC repositories found yet.