PoC Monitor
← All CVEs
CVE-2026-116448published 18 Nov 2026 14:35 UTCData: JSON · API

Dell PowerStore

Dell PowerStore SDNAS contains an OS Command Injection vulnerability that could allow an attacker with internal network access to execute arbitrary commands as root on the NAS node.

First public PoC 13 hafter publication · 19 Nov 2026
Public PoCs11 on GitHub
CVSS9.8critical · scored by CNA · CWE-78
CISA KEV Not listednot known exploited

Affected versions and mitigation

From the CVE record and the vendor's references.

Affected

Dell PowerStore 500T
  • < 5.1.0.0-2798105 or later

Fixed in 5.1.0.0-2798105 or later

Dell PowerStore 1000T
  • < 5.1.0.0-2798105 or later

Fixed in 5.1.0.0-2798105 or later

Dell PowerStore 1200T
  • < 5.1.0.0-2798105 or later

Fixed in 5.1.0.0-2798105 or later

Dell PowerStore 3000T
  • < 5.1.0.0-2798105 or later

Fixed in 5.1.0.0-2798105 or later

Dell PowerStore 3200Q
  • < 5.1.0.0-2798105 or later

Fixed in 5.1.0.0-2798105 or later

Dell PowerStore 3200T
  • < 5.1.0.0-2798105 or later

Fixed in 5.1.0.0-2798105 or later

Dell PowerStore 5000T
  • < 5.1.0.0-2798105 or later

Fixed in 5.1.0.0-2798105 or later

Dell PowerStore 5200Q
  • < 5.1.0.0-2798105 or later

Fixed in 5.1.0.0-2798105 or later

Dell PowerStore 5200T
  • < 5.1.0.0-2798105 or later

Fixed in 5.1.0.0-2798105 or later

Dell PowerStore 7000T
  • < 5.1.0.0-2798105 or later

Fixed in 5.1.0.0-2798105 or later

Dell PowerStore 9000T
  • < 5.1.0.0-2798105 or later

Fixed in 5.1.0.0-2798105 or later

Dell PowerStore 9200T
  • < 5.1.0.0-2798105 or later

Fixed in 5.1.0.0-2798105 or later

Dell PowerStore 1500
  • < 5.1.0.0-2798105 or later

Fixed in 5.1.0.0-2798105 or later

Dell PowerStore 5500
  • < 5.1.0.0-2798105 or later

Fixed in 5.1.0.0-2798105 or later

Dell PowerStore 9500
  • < 5.1.0.0-2798105 or later

Fixed in 5.1.0.0-2798105 or later

Mitigation

Upgrade PowerStore 500T to 5.1.0.0-2798105 or later or later.

Upgrade PowerStore 1000T to 5.1.0.0-2798105 or later or later.

Upgrade PowerStore 1200T to 5.1.0.0-2798105 or later or later.

Upgrade PowerStore 3000T to 5.1.0.0-2798105 or later or later.

Upgrade PowerStore 3200Q to 5.1.0.0-2798105 or later or later.

Upgrade PowerStore 3200T to 5.1.0.0-2798105 or later or later.

Upgrade PowerStore 5000T to 5.1.0.0-2798105 or later or later.

Upgrade PowerStore 5200Q to 5.1.0.0-2798105 or later or later.

Upgrade PowerStore 5200T to 5.1.0.0-2798105 or later or later.

Upgrade PowerStore 7000T to 5.1.0.0-2798105 or later or later.

Upgrade PowerStore 9000T to 5.1.0.0-2798105 or later or later.

Upgrade PowerStore 9200T to 5.1.0.0-2798105 or later or later.

Upgrade PowerStore 1500 to 5.1.0.0-2798105 or later or later.

Upgrade PowerStore 5500 to 5.1.0.0-2798105 or later or later.

Upgrade PowerStore 9500 to 5.1.0.0-2798105 or later or later.

References

Timeline

Days relative to CVE publication
-2t=0+2+4+6+8CVE published18 Nov 2026 · t = 0First public PoC19 Nov 2026 · t+13h

First public PoC 13 h after publication; not in CISA KEV. First PoC: LLCForge/CVE-2026-116448 (created 19 Nov 2026, found by us: 19 Nov 2026).

PoC repositories

Found on GitHub.

1 PoCs

PoCs 1
RepositoryCreatedFound by usStarsAssessment
LLCForge/CVE-2026-116448 19 Nov 2026 +13 h 19 Nov 2026 0 PoC
Flags · score 15
  • owner account created less than 30 days before the repo

Below the suspicion threshold (50); does not change the assessment.

Only PoCs count toward the first-PoC date and the characteristics below. Do not run PoC code from unknown sources.

PoC characteristics

What to hunt for in your logs · from 1 PoC repo

GET /api/rest/sdnas_node

Key headers
Dell-Emc-Token: {var}
Ports
8080
Seen in
1 repo: LLCForge/CVE-2026-116448
Evidence
LLCForge/CVE-2026-116448/README.md:122

POST /api/rest/login_sessions

Body markers
"username":"svc_monitor" "password":"Monitor1!" "is_async" in application/json
Ports
8080
Seen in
1 repo: LLCForge/CVE-2026-116448
Evidence
LLCForge/CVE-2026-116448/README.md:116

POST /api/rest/sdnas_node/NODE_ID/action/diagnose_network

Key headers
Dell-Emc-Token: {var}
Body markers
"nslookup_host":"8.8.8.8; id; hostname #" in application/json
Ports
8080
Seen in
1 repo: LLCForge/CVE-2026-116448
Evidence
LLCForge/CVE-2026-116448/README.md:126

Regex

Generated from PoC characteristics; not yet reviewed. Matches the request path and query.

GET /api/rest/sdnas_node
(?i)^/api/rest/sdnas_node(?:[?#].*)?$
POST /api/rest/login_sessions
(?i)^/api/rest/login_sessions(?:[?#].*)?$
POST /api/rest/sdnas_node/NODE_ID/action/diagnose_network
(?i)^/api/rest/sdnas_node/NODE_ID/action/diagnose_network(?:[?#].*)?$

Suricata

Template generated from PoC characteristics. Review before deploying.

GET /api/rest/sdnas_node
alert http any any -> $HOME_NET [8080] (msg:"GG PoC-Monitor CVE-2026-116448 Dell PowerStore exploit attempt"; flow:established,to_server; http.method; content:"GET"; http.uri; content:"/api/rest/sdnas_node"; http.header_names; content:"Dell-Emc-Token"; nocase; reference:url,poc.griffinguard.io/cve/CVE-2026-116448; classtype:web-application-attack; sid:9611550; rev:1;)
POST /api/rest/login_sessions
alert http any any -> $HOME_NET [8080] (msg:"GG PoC-Monitor CVE-2026-116448 Dell PowerStore exploit attempt"; flow:established,to_server; http.method; content:"POST"; http.uri; content:"/api/rest/login_sessions"; http.request_body; content:"|22|username|22|:|22|svc_monitor|22|"; http.request_body; content:"|22|password|22|:|22|Monitor1!|22|"; http.request_body; content:"|22|is_async|22|"; reference:url,poc.griffinguard.io/cve/CVE-2026-116448; classtype:web-application-attack; sid:9112901; rev:1;)
POST /api/rest/sdnas_node/NODE_ID/action/diagnose_network
alert http any any -> $HOME_NET [8080] (msg:"GG PoC-Monitor CVE-2026-116448 Dell PowerStore exploit attempt"; flow:established,to_server; http.method; content:"POST"; http.uri; content:"/api/rest/sdnas_node/NODE_ID/action/diagnose_network"; http.header_names; content:"Dell-Emc-Token"; nocase; http.request_body; content:"|22|nslookup_host|22|:|22|8.8.8.8|3b| id|3b| hostname #|22|"; reference:url,poc.griffinguard.io/cve/CVE-2026-116448; classtype:web-application-attack; sid:9351484; rev:1;)

Sigma

Template generated from PoC characteristics. Review before deploying.

GET /api/rest/sdnas_node
title: Dell PowerStore exploit attempt (CVE-2026-116448)
id: gg-pocmon-cve-2026-116448-9611550
status: experimental
description: Request pattern taken from public PoCs for CVE-2026-116448. Generated, not reviewed.
references:
  - https://poc.griffinguard.io/cve/CVE-2026-116448
logsource:
  category: webserver
detection:
  selection:
    cs-method: GET
    cs-uri-stem|contains|all:
      - '/api/rest/sdnas_node'
  condition: selection
falsepositives:
  - Authorized vulnerability scanning
level: critical
tags:
  - attack.initial_access
  - attack.t1190
  - cve.2026.116448
POST /api/rest/login_sessions
title: Dell PowerStore exploit attempt (CVE-2026-116448)
id: gg-pocmon-cve-2026-116448-9112901
status: experimental
description: Request pattern taken from public PoCs for CVE-2026-116448. Generated, not reviewed.
references:
  - https://poc.griffinguard.io/cve/CVE-2026-116448
logsource:
  category: webserver
detection:
  selection:
    cs-method: POST
    cs-uri-stem|contains|all:
      - '/api/rest/login_sessions'
  condition: selection
falsepositives:
  - Authorized vulnerability scanning
level: critical
tags:
  - attack.initial_access
  - attack.t1190
  - cve.2026.116448
POST /api/rest/sdnas_node/NODE_ID/action/diagnose_network
title: Dell PowerStore exploit attempt (CVE-2026-116448)
id: gg-pocmon-cve-2026-116448-9351484
status: experimental
description: Request pattern taken from public PoCs for CVE-2026-116448. Generated, not reviewed.
references:
  - https://poc.griffinguard.io/cve/CVE-2026-116448
logsource:
  category: webserver
detection:
  selection:
    cs-method: POST
    cs-uri-stem|contains|all:
      - '/api/rest/sdnas_node/NODE_ID/action/diagnose_network'
  condition: selection
falsepositives:
  - Authorized vulnerability scanning
level: critical
tags:
  - attack.initial_access
  - attack.t1190
  - cve.2026.116448