PoC Monitor
← All CVEs
CVE-2026-111735published 29 Oct 2026 15:42 UTCData: JSON · API

RT-Labs P-Net

Integer underflow leads to out-of-bounds read in pf_cpm_c_data_ind()

P-Net before 1.0.3 contains an integer underflow in pf_cpm_c_data_ind(). When handling a received cyclic data frame while the consumer is in the FRUN or RUN state, the offset of the APDU status was computed as the frame length minus 4 using 16-bit arithmetic, without checking that the frame is long enough. A crafted short frame makes the offset wrap around, so the function reads outside the receive buffer. This can cause a crash (denial of service) or disclose memory content.

First public PoC None yetno public PoC found
Public PoCs00 on GitHub
CVSS7.1high · scored by CNA · CWE-191
CISA KEV Not listednot known exploited

Affected versions and mitigation

From the CVE record and the vendor's references.

Affected

RT-Labs P-Net
  • < 1.0.3

Fixed in 1.0.3

Mitigation

Upgrade to P-Net 1.0.3 or later.

Timeline

Days relative to CVE publication
-2t=0+2+4+6+8CVE published29 Oct 2026 · t = 0

No public PoC found yet; not in CISA KEV.

PoC repositories

Found on GitHub.

No PoC repositories found yet.