GlavSoft TightVNC
Out-of-bounds read in TightVNC Viewer ZRLE palette decoding
An out-of-bounds read vulnerability in the ZRLE decoder of GlavSoft TightVNC Viewer for Windows before 2.8.88 allows a malicious or compromised VNC server to read heap memory beyond the palette allocation and crash the viewer by sending ZRLE-encoded tiles whose palette indices exceed the declared palette size. readPaletteRleTile() and readPackedPaletteTile() use the attacker-supplied index to look up colours without validating it against the palette size; out-of-bounds heap data is copied into the framebuffer (garbled display) or the read faults, terminating the viewer.
Affected versions and mitigation
From the CVE record and the vendor's references.Affected
- < 2.8.88
Fixed in 2.8.88
Mitigation
Upgrade TightVNC for Windows to version 2.8.88 or later.
Workaround
Connect only to trusted VNC servers until the viewer is upgraded.
References
Timeline
Days relative to CVE publicationNo public PoC found yet; not in CISA KEV.
PoC repositories
Found on GitHub.No PoC repositories found yet.