Altium Enterprise Server
Stored Cross-Site Scripting in Altium Enterprise Server Workflow Engine Allows Privilege Escalation
A stored cross-site scripting (XSS) vulnerability exists in the Altium Workflow Engine due to missing server-side input sanitization in workflow form submission APIs. A regular authenticated user can inject arbitrary JavaScript into workflow data. When an administrator views the affected workflow, the injected payload executes in the administrator’s browser context, allowing privilege escalation, including creation of new administrator accounts, session token theft, and execution of administrative actions.
Affected versions and mitigation
From the CVE record and the vendor's references.Affected
- <= 8.0.1
Mitigation
The record names no fix. Check the vendor advisory below.
Timeline
Days relative to CVE publicationFirst public PoC 199 days after publication; not in CISA KEV. First PoC: George0Papasotiriou/CVE-2026-1010-WebSocket-Connection-Smuggling-via-Malformed-Upgrade-Header (created 3 Aug 2026, found by us: backfilled).
PoC repositories
Found on GitHub.1 PoCs
PoCs 1
| Repository | Created | Stars | Assessment |
|---|---|---|---|
| George0Papasotiriou/CVE-2026-1010-WebSocket-Connection-Smuggling-via-Malformed-Upgrade-Header | 3 Aug 2026 +199 d | 1 | PoC |
Only PoCs count toward the first-PoC date and the characteristics below. Do not run PoC code from unknown sources.
PoC characteristics
What to hunt for in your logs · from 1 PoC repoGET /
- Key headers
Connection: UpgradeContent-Length: 0Sec-WebSocket-Key: dGhlIHNhbXBsZSBub25jZQ==Upgrade: websocket- Ports
- 8080
- PoC User-Agent
body_markers- Seen in
- 1 repo: George0Papasotiriou/CVE-2026-1010-WebSocket-Connection-Smuggling-via-Malformed-Upgrade-Header
- Evidence
- George0Papasotiriou/CVE-2026-1010-WebSocket-Connection-Smuggling-via-Malformed-Upgrade-Header/exploit_ws_smuggling.py:6-21
Regex
Generated from PoC characteristics; not yet reviewed. Matches the request path and query.
(?i)^/(?:[?#].*)?$
Suricata
Template generated from PoC characteristics. Review before deploying.
alert http any any -> $HOME_NET [8080] (msg:"GG PoC-Monitor CVE-2026-1010 Altium Altium Enterprise Server exploit attempt"; flow:established,to_server; http.method; content:"GET"; http.header; content:"Connection: Upgrade"; nocase; http.header; content:"Content-Length: 0"; nocase; http.header; content:"Sec-WebSocket-Key: dGhlIHNhbXBsZSBub25jZQ=="; nocase; http.header; content:"Upgrade: websocket"; nocase; reference:url,poc.griffinguard.io/cve/CVE-2026-1010; classtype:web-application-attack; sid:9699558; rev:1;)
Sigma
Template generated from PoC characteristics. Review before deploying.
title: Altium Altium Enterprise Server exploit attempt (CVE-2026-1010)
id: gg-pocmon-cve-2026-1010-9699558
status: experimental
description: Request pattern taken from public PoCs for CVE-2026-1010. Generated, not reviewed.
references:
- https://poc.griffinguard.io/cve/CVE-2026-1010
logsource:
category: webserver
detection:
selection:
cs-method: GET
condition: selection
falsepositives:
- Authorized vulnerability scanning
level: high
tags:
- attack.initial_access
- attack.t1190
- cve.2026.1010