RUCKUS Networks vRIoT IOT Controller
Ruckus vRIoT IoT Controller < 3.0.0.0 Hardcoded SSH Credentials RCE
Edge device · Router / network deviceknown edge product: RUCKUS Networks vRIoT IOT Controller Ruckus vRIoT IoT (high confidence)
The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) contain hardcoded credentials for an operating system user account within an initialization script. The SSH service is network-accessible without IP-based restrictions. Although the configuration disables SCP and pseudo-TTY allocation, an attacker can authenticate using the hardcoded credentials and establish SSH local port forwarding to access the Docker socket. By mounting the host filesystem via Docker, an attacker can escape the container and execute arbitrary OS commands as root on the underlying vRIoT controller, resulting in complete system compromise.
Affected versions and mitigation
From the CVE record and the vendor's references.Affected
- >= 2.3.0.0 (GA), < 3.0.0.0 (GA)
- >= 2.3.1.0 (MR), < 3.0.0.0 (GA)
- >= 2.4.0.0 (GA), < 3.0.0.0 (GA)
Fixed in 3.0.0.0 (GA)
Mitigation
Upgrade vRIoT IOT Controller to 3.0.0.0 (GA) or later.
References
- Vendor advisory support.ruckuswireless.com/security_bulletins/336
Timeline
Days relative to CVE publicationNo public PoC found yet; not in CISA KEV.
PoC repositories
Found on GitHub.No PoC repositories found yet.