Dormakaba Access Manager 92xx-k5
Trace Functionality Leaking Sensitive Data in dormakaba access manager
The Access Manager is offering a trace functionality to debug errors and issues with the device. The trace functionality is implemented as a simple TCP socket. A tool called TraceClient.exe, provided by dormakaba via the Access Manager web interface, is used to connect to the socket and receive debug information. The data is permanently broadcasted on the TCP socket. The socket can be accessed without any authentication or encryption. The transmitted data is based on the set verbosity level. The verbosity level can be set using the http(s) endpoint with the service interface password or with the guessable identifier of the device via the SOAP interface. The transmitted data contains sensitive data like the Card ID as well as all button presses on Registration units. This allows an attacker with network level access to retrieve all entered PINs on a registration unit.
Affected versions and mitigation
From the CVE record and the vendor's references.Affected
- 92xx-K5: <XAMB 04.06.212
- 92xx-K7: <BAME 05.02.156
Mitigation
To secure the Access Manager 92xx, it is highly recommended to update to the latest FW, at least XAMB 04.06.212 RA.
References
- Vendor advisory dormakabagroup.com/en/security-advisories
Timeline
Days relative to CVE publicationNo public PoC found yet; not in CISA KEV.
PoC repositories
Found on GitHub.No PoC repositories found yet.