Juniper Networks Junos OS
Junos OS: SRX300 Series: rpd will crash upon receiving a specific, valid BGP UPDATE message
Edge device · Router / network deviceknown edge product: Juniper Networks Junos OS Junos OS: SRX300 Series: (high confidence)
A Use of Incorrect Byte Ordering vulnerability in the Routing Protocol Daemon (rpd) of Juniper Networks Junos OS on SRX300 Series allows an unauthenticated, network-based attacker to cause a Denial-of-Service (DoS). When a BGP update is received over an established BGP session which contains a specific, valid, optional, transitive path attribute, rpd will crash and restart. This issue affects eBGP and iBGP over IPv4 and IPv6. This issue affects: Junos OS: * 22.1 versions from 22.1R1 before 22.2R3-S4, * 22.3 versions before 22.3R3-S3, * 22.4 versions before 22.4R3-S2, * 23.2 versions before 23.2R2, * 23.4 versions before 23.4R2.
Affected versions and mitigation
From the CVE record and the vendor's references.Affected
- >= 22.2, < 22.2R3-S4
- >= 22.3, < 22.3R3-S3
- >= 22.4, < 22.4R3-S2
- >= 23.2, < 23.2R2
- >= 23.4, < 23.4R2
Fixed in 22.2R3-S4, 22.3R3-S3, 22.4R3-S2, 23.2R2, 23.4R2, 0
Mitigation
The following software releases have been updated to resolve this specific issue: Junos OS: 22.2R3-S4, 22.3R3-S3, 22.4R3-S2, 23.2R2, 23.4R2, 24.2R1, and all subsequent releases.
Workaround
There are no known workarounds for this issue.
References
- Vendor advisory supportportal.juniper.net/JSA100084
Timeline
Days relative to CVE publicationNo public PoC found yet; not in CISA KEV.
PoC repositories
Found on GitHub.No PoC repositories found yet.