PoC Monitor
← All CVEs
CVE-2025-40567published 10 Jun 2025 15:17 UTCData: JSON · API

Siemens RUGGEDCOM RST2428P

A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). The "Load Rollback" functionality in the web interface of affected products contains an incorrect authorization check vulnerability. This could allow an authenticated remote attacker with "guest" role to make the affected product roll back configuration changes made by privileged users.

First public PoC None yetno public PoC found
Public PoCs00 on GitHub
CVSS7.1high · scored by CNA · CWE-863
CISA KEV Not listednot known exploited

Affected versions and mitigation

From the CVE record and the vendor's references.

Affected

Siemens RUGGEDCOM RST2428P
  • < V3.2

Fixed in V3.2

Siemens SCALANCE XCH328
  • < V3.2

Fixed in V3.2

Siemens SCALANCE XCM324
  • < V3.2

Fixed in V3.2

Siemens SCALANCE XCM328
  • < V3.2

Fixed in V3.2

Siemens SCALANCE XCM332
  • < V3.2

Fixed in V3.2

Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC)
  • < V3.2

Fixed in V3.2

Siemens SCALANCE XRM334 (230 V AC, 12xFO)
  • < V3.2

Fixed in V3.2

Siemens SCALANCE XRM334 (230 V AC, 8xFO)
  • < V3.2

Fixed in V3.2

Siemens SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)
  • < V3.2

Fixed in V3.2

Siemens SCALANCE XRM334 (24 V DC, 12xFO)
  • < V3.2

Fixed in V3.2

Siemens SCALANCE XRM334 (24 V DC, 8xFO)
  • < V3.2

Fixed in V3.2

Siemens SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)
  • < V3.2

Fixed in V3.2

Siemens SCALANCE XRM334 (2x230 V AC, 12xFO)
  • < V3.2

Fixed in V3.2

Siemens SCALANCE XRM334 (2x230 V AC, 8xFO)
  • < V3.2

Fixed in V3.2

Siemens SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)
  • < V3.2

Fixed in V3.2

Mitigation

Upgrade RUGGEDCOM RST2428P to V3.2 or later.

Upgrade SCALANCE XCH328 to V3.2 or later.

Upgrade SCALANCE XCM324 to V3.2 or later.

Upgrade SCALANCE XCM328 to V3.2 or later.

Upgrade SCALANCE XCM332 to V3.2 or later.

Upgrade SCALANCE XRH334 (24 V DC, 8xFO, CC) to V3.2 or later.

Upgrade SCALANCE XRM334 (230 V AC, 12xFO) to V3.2 or later.

Upgrade SCALANCE XRM334 (230 V AC, 8xFO) to V3.2 or later.

Upgrade SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) to V3.2 or later.

Upgrade SCALANCE XRM334 (24 V DC, 12xFO) to V3.2 or later.

Upgrade SCALANCE XRM334 (24 V DC, 8xFO) to V3.2 or later.

Upgrade SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) to V3.2 or later.

Upgrade SCALANCE XRM334 (2x230 V AC, 12xFO) to V3.2 or later.

Upgrade SCALANCE XRM334 (2x230 V AC, 8xFO) to V3.2 or later.

Upgrade SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) to V3.2 or later.

Timeline

Days relative to CVE publication
-2t=0+2+4+6+8CVE published10 Jun 2025 · t = 0

No public PoC found yet; not in CISA KEV.

PoC repositories

Found on GitHub.

No PoC repositories found yet.