Vestel AC Charger EVC04
Vestel AC Charger Exposure of Sensitive System Information to an Unauthorized Control Sphere
Vestel AC Charger version 3.75.0 contains a vulnerability that could enable an attacker to access files containing sensitive information, such as credentials which could be used to further compromise the device.
Affected versions and mitigation
From the CVE record and the vendor's references.Affected
- 3.75.0
Mitigation
Vestel strongly suggests that users of the related AC chargers update to version V3.187 or a higher version.
Workaround
Avoid using open network: * Use secure methods like virtual private networks (VPNs) for remote access. Regularly update VPNs to their latest versions and ensure that connected devices maintain strong security measures. * Reduce network exposure for applications and endpoints. Only make them accessible via the Internet if specifically designed for and required by their intended use. Login Credentials Management: * Force end user to revise the factory default set username and password of webconfig page. * Remove any printed documents such as installation guide, instruction book, quick start guide from web where login credentials are featured. Please refer to Vestel's advisory https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F1%2FVSA-1_R2.pdf for more information.
Timeline
Days relative to CVE publicationNo public PoC found yet; not in CISA KEV.
PoC repositories
Found on GitHub.No PoC repositories found yet.