Siemens TeleControl Server Basic
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
First public PoC
None yetno public PoC found
Public PoCs00 on GitHub
CVSS8.8high · scored by CNA · CWE-89
CISA KEV
Not listednot known exploited
Affected versions and mitigation
From the CVE record and the vendor's references.Affected
Siemens TeleControl Server Basic
- < V3.1.2.2
Fixed in V3.1.2.2
Mitigation
Upgrade TeleControl Server Basic to V3.1.2.2 or later.
Timeline
Days relative to CVE publicationNo public PoC found yet; not in CISA KEV.
PoC repositories
Found on GitHub.No PoC repositories found yet.