Siemens Automation License Manager V6.0
The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.
Affected versions and mitigation
From the CVE record and the vendor's references.Affected
- < *
Fixed in *
- < V6.2 Upd3
Fixed in V6.2 Upd3
- < *
Fixed in *
- < *
Fixed in *
- < V6.9
Fixed in V6.9
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < V1.5.5.0
Fixed in V1.5.5.0
- < *
Fixed in *
- < *
Fixed in *
- < V2.0 SP2
Fixed in V2.0 SP2
- < V5.0 SP4
Fixed in V5.0 SP4
- < V5.0 SP4
Fixed in V5.0 SP4
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < V3.1.0.2
Fixed in V3.1.0.2
- < V4.1
Fixed in V4.1
- < V10.0 SP1
Fixed in V10.0 SP1
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < V19 Update 4
Fixed in V19 Update 4
- < *
Fixed in *
- < V2.0 Upd3
Fixed in V2.0 Upd3
- < V9.1 SP1 Upd8
Fixed in V9.1 SP1 Upd8
- < V9.1 SP1 Upd8
Fixed in V9.1 SP1 Upd8
- < V2.1
Fixed in V2.1
- < *
Fixed in *
- < V4.1.0.1
Fixed in V4.1.0.1
- < V5.0.0.1
Fixed in V5.0.0.1
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < V20.0 Update 1
Fixed in V20.0 Update 1
- < *
Fixed in *
- < V9.1 SP2 Upd4
Fixed in V9.1 SP2 Upd4
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < V9.1 SP2 Upd6
Fixed in V9.1 SP2 Upd6
- < V9.1 SP2 Upd2
Fixed in V9.1 SP2 Upd2
- < V10.0 SP1 Upd2
Fixed in V10.0 SP1 Upd2
- < V9.1 SP2 Upd8
Fixed in V9.1 SP2 Upd8
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < V9.1 Upd8
Fixed in V9.1 Upd8
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < V10.0 SP1 UC01
Fixed in V10.0 SP1 UC01
- < V9.1 SP1 UC08
Fixed in V9.1 SP1 UC08
- < *
Fixed in *
- < *
Fixed in *
- < V6.0 SP1
Fixed in V6.0 SP1
- < *
Fixed in *
- < *
Fixed in *
- < V9.3 SP1 Upd2
Fixed in V9.3 SP1 Upd2
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < V2024 SP1 Upd2
Fixed in V2024 SP1 Upd2
- < V17 Update 9
Fixed in V17 Update 9
- < *
Fixed in *
- < V19 Update 4
Fixed in V19 Update 4
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < V31.1.5
Fixed in V31.1.5
- < V4.0.1
Fixed in V4.0.1
- < V3.5 SP4 Update 1
Fixed in V3.5 SP4 Update 1
- < V7.0 Update 1
Fixed in V7.0 Update 1
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < V20 Update 1
Fixed in V20 Update 1
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < V6.0 SP3
Fixed in V6.0 SP3
- < *
Fixed in *
- < V17 Update 9
Fixed in V17 Update 9
- < V21
Fixed in V21
- < *
Fixed in *
- < *
Fixed in *
- < V20
Fixed in V20
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < V20
Fixed in V20
- < V7.5 SP2 Update 20
Fixed in V7.5 SP2 Update 20
- < V8.0 Update 8
Fixed in V8.0 Update 8
- < V8.1 Update 3
Fixed in V8.1 Update 3
- < V17 Update 9
Fixed in V17 Update 9
- < V18 Update 6
Fixed in V18 Update 6
- < V19 Update 4
Fixed in V19 Update 4
- < V20 Update 3
Fixed in V20 Update 3
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < V4.0
Fixed in V4.0
- < *
Fixed in *
- < *
Fixed in *
- < *
Fixed in *
- < V3.1.2.2
Fixed in V3.1.2.2
- < V3.0.6
Fixed in V3.0.6
- < V2.3
Fixed in V2.3
- < *
Fixed in *
- < *
Fixed in *
- < V19 Update 4
Fixed in V19 Update 4
- < V20 Update 3
Fixed in V20 Update 3
- < V2.2
Fixed in V2.2
- < *
Fixed in *
- < V17 Update 9
Fixed in V17 Update 9
- < V18 Update 6
Fixed in V18 Update 6
- < V19 Update 4
Fixed in V19 Update 4
- < V20 Update 4
Fixed in V20 Update 4
- < V17 Update 9
Fixed in V17 Update 9
Mitigation
Upgrade Automation License Manager V6.0 to * or later.
Upgrade Automation License Manager V6.2 to V6.2 Upd3 or later.
Upgrade CEMAT V10.0 to * or later.
Upgrade CP PtP Param configuring interface to * or later.
Upgrade Create MyConfig (CMC) to V6.9 or later.
Upgrade Energy Support Library (EnSL) to * or later.
Upgrade FM Configuration Package to * or later.
Upgrade Modular PID CTRL Tool to * or later.
Upgrade MultiFieldbus Configuration Tool (MFCT) to V1.5.5.0 or later.
Upgrade OpenPCS 7 V10.0 to * or later.
Upgrade OpenPCS 7 V9.1 to * or later.
Upgrade Siemens Network Planner (SINETPLAN) to V2.0 SP2 or later.
Upgrade SIMATIC Automation Tool to V5.0 SP4 or later.
Upgrade SIMATIC Automation Tool SDK Windows to V5.0 SP4 or later.
Upgrade SIMATIC BATCH V10.0 to * or later.
Upgrade SIMATIC BATCH V9.1 to * or later.
Upgrade SIMATIC Control Function Library (CFL) V1.x to * or later.
Upgrade SIMATIC Control Function Library (CFL) V2.x to * or later.
Upgrade SIMATIC Control Function Library (CFL) V3.x to V3.1.0.2 or later.
Upgrade SIMATIC Control Function Library (CFL) V4.x to V4.1 or later.
Upgrade SIMATIC D7-SYS to V10.0 SP1 or later.
Upgrade SIMATIC eaSie Core Package (6DL5424-0AX00-0AV8) to * or later.
Upgrade SIMATIC eaSie Document Skills V26 to * or later.
Upgrade SIMATIC eaSie PCS 7 Skill Package V26 (6DL5424-0BX00-0AV8) to * or later.
Upgrade SIMATIC eaSie Workflow Skills V26 to * or later.
Upgrade SIMATIC Energy Suite V17 to * or later.
Upgrade SIMATIC Energy Suite V18 to * or later.
Upgrade SIMATIC Energy Suite V19 to V19 Update 4 or later.
Upgrade SIMATIC Logon V1.6 to * or later.
Upgrade SIMATIC Logon V2.0 to V2.0 Upd3 or later.
Upgrade SIMATIC Management Agent to V9.1 SP1 Upd8 or later.
Upgrade SIMATIC Management Console to V9.1 SP1 Upd8 or later.
Upgrade SIMATIC MTP CREATOR V2.x to V2.1 or later.
Upgrade SIMATIC MTP CREATOR V3.x to * or later.
Upgrade SIMATIC MTP CREATOR V4.x to V4.1.0.1 or later.
Upgrade SIMATIC MTP CREATOR V5.x to V5.0.0.1 or later.
Upgrade SIMATIC MTP Integrator V1.x to * or later.
Upgrade SIMATIC MTP Integrator V2.x to * or later.
Upgrade SIMATIC NET PC Software V16 to * or later.
Upgrade SIMATIC NET PC Software V17 to * or later.
Upgrade SIMATIC NET PC Software V18 to * or later.
Upgrade SIMATIC NET PC Software V19 to * or later.
Upgrade SIMATIC NET PC Software V20 to V20.0 Update 1 or later.
Upgrade SIMATIC ODK 1500S to * or later.
Upgrade SIMATIC PCS 7 Advanced Process Faceplates V9.1 to V9.1 SP2 Upd4 or later.
Upgrade SIMATIC PCS 7 Advanced Process Functions V2.1 to * or later.
Upgrade SIMATIC PCS 7 Advanced Process Functions V2.2 to * or later.
Upgrade SIMATIC PCS 7 Advanced Process Graphics V10.0 to * or later.
Upgrade SIMATIC PCS 7 Advanced Process Graphics V9.1 to * or later.
Upgrade SIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0 to * or later.
Upgrade SIMATIC PCS 7 Advanced Process Library V9.1 to V9.1 SP2 Upd6 or later.
Upgrade SIMATIC PCS 7 Basis Faceplates V9.1 to V9.1 SP2 Upd2 or later.
Upgrade SIMATIC PCS 7 Basis Library V10.0 to V10.0 SP1 Upd2 or later.
Upgrade SIMATIC PCS 7 Basis Library V9.1 to V9.1 SP2 Upd8 or later.
Upgrade SIMATIC PCS 7 Industry Library V10.0 to * or later.
Upgrade SIMATIC PCS 7 Industry Library V9.0 to * or later.
Upgrade SIMATIC PCS 7 Industry Library V9.1 to * or later.
Upgrade SIMATIC PCS 7 Logic Matrix V10.0 to * or later.
Upgrade SIMATIC PCS 7 Logic Matrix V9.1 to V9.1 Upd8 or later.
Upgrade SIMATIC PCS 7 MPC Configurator to * or later.
Upgrade SIMATIC PCS 7 PowerControl V9.1 to * or later.
Upgrade SIMATIC PCS 7 Standard Chemical Library V10.0 to * or later.
Upgrade SIMATIC PCS 7 Standard Chemical Library V9.1 to * or later.
Upgrade SIMATIC PCS 7 TeleControl V9.1 to * or later.
Upgrade SIMATIC PCS 7 V10.0 to V10.0 SP1 UC01 or later.
Upgrade SIMATIC PCS 7 V9.1 to V9.1 SP1 UC08 or later.
Upgrade SIMATIC PCS 7/OPEN OS V9.1 to * or later.
Upgrade SIMATIC PCS neo V5.0 to * or later.
Upgrade SIMATIC PCS neo V6.0 to V6.0 SP1 or later.
Upgrade SIMATIC PDM Maintenance Station V5.0 to * or later.
Upgrade SIMATIC PDM V9.2 to * or later.
Upgrade SIMATIC PDM V9.3 to V9.3 SP1 Upd2 or later.
Upgrade SIMATIC Process Function Library (PFL) V4.0 to * or later.
Upgrade SIMATIC Process Historian 2020 to * or later.
Upgrade SIMATIC Process Historian 2022 to * or later.
Upgrade SIMATIC Process Historian 2024 to V2024 SP1 Upd2 or later.
Upgrade SIMATIC ProSave V17 to V17 Update 9 or later.
Upgrade SIMATIC ProSave V18 to * or later.
Upgrade SIMATIC ProSave V19 to V19 Update 4 or later.
Upgrade SIMATIC ProSave V20 to * or later.
Upgrade SIMATIC Route Control V10.0 to * or later.
Upgrade SIMATIC Route Control V9.1 to * or later.
Upgrade SIMATIC S7 F Systems V6.3 to * or later.
Upgrade SIMATIC S7 F Systems V6.4 to * or later.
Upgrade SIMATIC S7-1500 Software Controller V2 to * or later.
Upgrade SIMATIC S7-1500 Software Controller V3 to V31.1.5 or later.
Upgrade SIMATIC S7-Fail-safe Configuration Tool (S7-FCT) to V4.0.1 or later.
Upgrade SIMATIC S7-PCT to V3.5 SP4 Update 1 or later.
Upgrade SIMATIC S7-PLCSIM Advanced to V7.0 Update 1 or later.
Upgrade SIMATIC S7-PLCSIM V17 to * or later.
Upgrade SIMATIC S7-PLCSIM V18 to * or later.
Upgrade SIMATIC S7-PLCSIM V19 to * or later.
Upgrade SIMATIC S7-PLCSIM V20 to V20 Update 1 or later.
Upgrade SIMATIC Safety Matrix V6.3 to * or later.
Upgrade SIMATIC STEP 7 CFC V19 to * or later.
Upgrade SIMATIC STEP 7 CFC V20 to * or later.
Upgrade SIMATIC STEP 7 V5.7 to * or later.
Upgrade SIMATIC Target to V6.0 SP3 or later.
Upgrade SIMATIC WinCC flexible ES to * or later.
Upgrade SIMATIC WinCC Runtime Advanced to V17 Update 9 or later.
Upgrade SIMATIC WinCC Runtime Professional to V21 or later.
Upgrade SIMATIC WinCC Runtime Professional V20 to * or later.
Upgrade SIMATIC WinCC TeleControl to * or later.
Upgrade SIMATIC WinCC Unified Line Coordination to V20 or later.
Upgrade SIMATIC WinCC Unified PC Runtime V18 to * or later.
Upgrade SIMATIC WinCC Unified PC Runtime V19 to * or later.
Upgrade SIMATIC WinCC Unified PC Runtime V20 to * or later.
Upgrade SIMATIC WinCC Unified Sequence to V20 or later.
Upgrade SIMATIC WinCC V7.5 to V7.5 SP2 Update 20 or later.
Upgrade SIMATIC WinCC V8.0 to V8.0 Update 8 or later.
Upgrade SIMATIC WinCC V8.1 to V8.1 Update 3 or later.
Upgrade SIMATIC WinCC Visualization Architect (SiVArc) V17 to V17 Update 9 or later.
Upgrade SIMATIC WinCC Visualization Architect (SiVArc) V18 to V18 Update 6 or later.
Upgrade SIMATIC WinCC Visualization Architect (SiVArc) V19 to V19 Update 4 or later.
Upgrade SIMATIC WinCC Visualization Architect (SiVArc) V20 to V20 Update 3 or later.
Upgrade SIMIT Rapid Tester to * or later.
Upgrade SIMIT Simulation Platform to * or later.
Upgrade SINAMICS Startdrive V17 to * or later.
Upgrade SINAMICS Startdrive V18 to * or later.
Upgrade SINAMICS Startdrive V19 to * or later.
Upgrade SINAMICS Startdrive V20 to * or later.
Upgrade SINEC NMS to V4.0 or later.
Upgrade SINEMA Remote Connect Client to * or later.
Upgrade SITRANS to * or later.
Upgrade Standard PID CTRL Tool to * or later.
Upgrade TeleControl Server Basic V3.1 to V3.1.2.2 or later.
Upgrade TIA Administrator to V3.0.6 or later.
Upgrade TIA Portal Cloud Connector to V2.3 or later.
Upgrade TIA Portal Test Suite V17 to * or later.
Upgrade TIA Portal Test Suite V18 to * or later.
Upgrade TIA Portal Test Suite V19 to V19 Update 4 or later.
Upgrade TIA Portal Test Suite V20 to V20 Update 3 or later.
Upgrade TIA Project-Server to V2.2 or later.
Upgrade TIA Project-Server V17 to * or later.
Upgrade Totally Integrated Automation Portal (TIA Portal) V17 to V17 Update 9 or later.
Upgrade Totally Integrated Automation Portal (TIA Portal) V18 to V18 Update 6 or later.
Upgrade Totally Integrated Automation Portal (TIA Portal) V19 to V19 Update 4 or later.
Upgrade Totally Integrated Automation Portal (TIA Portal) V20 to V20 Update 4 or later.
Upgrade WinCC Panel Image Setup to V17 Update 9 or later.
Timeline
Days relative to CVE publicationNo public PoC found yet; not in CISA KEV.
PoC repositories
Found on GitHub.No PoC repositories found yet.