  "title": "Arbitrary supervisor-mode function pointer injection via charger_set_prop() syscall in the charger driver API",
  "vendor": "zephyrproject",
  "product": "zephyr",
  "cvss": {
    "score": 7.8,
    "source": "cna",
    "vector": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": null,
  "description": "The user-mode syscall verifiers for the charger driver API in drivers/charger/charger_handlers.c did not inspect the prop argument before copying union charger_propval across the user/kernel boundary. Two members of that union are function pointers — status_notification (CHARGER_PROP_STATUS_NOTIFICATION) and online_notification (CHARGER_PROP_ONLINE_NOTIFICATION), declared in include/zephyr/drivers/charger.h — and z_vrfy_charger_set_prop() forwarded the caller-supplied union verbatim to the driver's set_property callback for any property. z_vrfy_charger_get_prop() had the mirror defect and copied the stored kernel callback address back out to user memory.\n\nWith CONFIG_USERSPACE enabled, any user-mode thread that has been granted a charger device object could call charger_set_prop() with CHARGER_PROP_STATUS_NOTIFICATION or CHARGER_PROP_ONLINE_NOTIFICATION and an arbitrary pointer value. Drivers that implement these properties — drivers/charger/charger_max20335.c, drivers/charger/charger_pf1550.c and drivers/charger/charger_bq2518x.c — store the pointer in device data and later invoke it from their interrupt work handlers, which run in supervisor mode, on any charger state change such as a cable plug/unplug.\n\nThe result is a control-flow hijack at kernel privilege from an unprivileged thread, defeating the isolation that CONFIG_USERSPACE is meant to provide; the read path additionally disclosed a kernel code address to user mode, and clearing a notifier installed by a supervisor thread let user mode suppress charger notifications. Supervisor-mode callers of charger_set_prop()/charger_get_prop() are unaffected.\n\nThe fix makes both verifiers reject the two notifier properties outright — including when the supplied callback is NULL, since the notifiers are device state — and adds a BUILD_ASSERT on CHARGER_PROP_COMMON_COUNT so that new properties force a re-review of the union's user-mode safety.",
  "cwe": "CWE-822",
  "cvss_by_source": {
    "cna": 7.8
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "zephyrproject",
        "product": "zephyr",
        "ranges": [
          "\u003e= 3.7.0, \u003c 4.3.2",
          "\u003e= 4.4.0, \u003c 4.5.0"
        ],
        "fixed_in": [
          "4.3.2",
          "4.5.0"
        ]
      }
    ],
    "upgrade": [
      "Upgrade zephyr to 4.3.2 or 4.5.0 or later."
    ],
    "references": [
      {
        "kind": "Patch",
        "url": "https://github.com/zephyrproject-rtos/zephyr/commit/5467b7a73fe093d7e9562ee15c321cf8f1639d17"
      },
      {
        "kind": "Vendor advisory",
        "url": "https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-jr35-f52j-fm88"
      }
    ]
  },
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}