  "id": "CVE-2026-89202",
  "url": "https://poc.griffinguard.io/cve/CVE-2026-89202",
  "published_at": "2026-10-13T09:19:06.397Z",
  "vendor": "Siemens",
  "product": "RUGGEDCOM CROSSBOW",
  "cvss": {
    "score": 7.1,
    "source": "cna",
    "vector": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": null,
  "description": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V6.0). Affected devices do not properly perform authorization checks for device disconnection requests. This could allow an authenticated attacker with minimal privileges to disconnect active sessions of other users, including administrators, leading to a denial of service.",
  "cwe": "CWE-639",
  "cvss_by_source": {
    "cna": 7.1
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "Siemens",
        "product": "RUGGEDCOM CROSSBOW",
        "ranges": [
          "\u003c V6.0"
        ],
        "fixed_in": [
          "V6.0"
        ]
      }
    ],
    "upgrade": [
      "Upgrade RUGGEDCOM CROSSBOW to V6.0 or later."
    ]
  },
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}