  "id": "CVE-2026-81574",
  "url": "https://poc.griffinguard.io/cve/CVE-2026-81574",
  "published_at": "2026-08-27T07:11:56.916Z",
  "title": "Format String Vulnerability in Logger",
  "vendor": "wibu-systems-ag",
  "product": "codemeter-runtime",
  "cvss": {
    "score": 8.2,
    "source": "cna",
    "vector": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": null,
  "description": "In CodeMeter Runtime before versions 8.41a and 9.10, the logger does not sanitize input strings in certain cases, allowing an attacker to inject printf-style format\nspecifiers. This can be used to reliably crash CodeMeter and disclose sensitive information such as process memory\nand stack canaries. The attack works locally, for example by using cmu --set-proxy to set the proxy value, and\nremotely when combined with CVE-2026-81573 by setting General.ProxyServer and then triggering this\nvulnerability.",
  "cwe": "CWE-134",
  "cvss_by_source": {
    "cna": 8.2
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "wibu-systems-ag",
        "product": "codemeter-runtime",
        "ranges": [
          "\u003e= 9.00, \u003c 9.10",
          "\u003e= 8.00, \u003c 8.41a",
          "7.00"
        ],
        "fixed_in": [
          "9.10",
          "8.41a",
          "6.00"
        ]
      }
    ],
    "upgrade": [
      "Upgrade codemeter-runtime to 9.10 or 8.41a or 6.00 or later."
    ],
    "references": [
      {
        "kind": "Vendor advisory",
        "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-103401.pdf"
      }
    ]
  },
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}