  "id": "CVE-2026-76992",
  "url": "https://poc.griffinguard.io/cve/CVE-2026-76992",
  "published_at": "2026-09-30T11:07:45.751Z",
  "title": "Uncontrolled Memory Allocation in CODESYS Gateway Client",
  "vendor": "CODESYS",
  "product": "Development System 3",
  "cvss": {
    "score": 8.7,
    "source": "cna",
    "vector": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": null,
  "description": "The CODESYS Gateway Client allocates memory based on a size field in a gateway response without enforcing an appropriate upper limit. An unauthenticated remote attacker controlling a malicious gateway can exploit this behavior to trigger excessive memory consumption, resulting in a denial-of-service condition thus leading to a total loss of availablity.",
  "cwe": "CWE-770",
  "cvss_by_source": {
    "cna": 8.7
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "CODESYS",
        "product": "Development System 3",
        "ranges": [
          "\u003e= 3.0.0.0, \u003c 3.5.22.40"
        ],
        "fixed_in": [
          "3.5.22.40"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "Gateway",
        "ranges": [
          "\u003e= 3.0.0.0, \u003c 3.5.22.40"
        ],
        "fixed_in": [
          "3.5.22.40"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "Edge Gateway for Windows",
        "ranges": [
          "\u003e= 3.0.0.0, \u003c 3.5.22.40"
        ],
        "fixed_in": [
          "3.5.22.40"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "HMI (SL)",
        "ranges": [
          "\u003e= 3.0.0.0, \u003c 3.5.22.40"
        ],
        "fixed_in": [
          "3.5.22.40"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "OPC DA Server SL",
        "ranges": [
          "\u003e= 3.0.0.0, \u003c 3.5.22.40"
        ],
        "fixed_in": [
          "3.5.22.40"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "PLCHandler",
        "ranges": [
          "\u003e= 3.0.0.0, \u003c 3.5.22.40"
        ],
        "fixed_in": [
          "3.5.22.40"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "Runtime Toolkit",
        "ranges": [
          "\u003e= 3.0.0.0, \u003c 3.5.22.40"
        ],
        "fixed_in": [
          "3.5.22.40"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "Edge Gateway for Linux",
        "ranges": [
          "\u003e= 3.15.0.0, \u003c 4.23.0.0"
        ],
        "fixed_in": [
          "4.23.0.0"
        ]
      }
    ],
    "upgrade": [
      "Upgrade Development System 3 to 3.5.22.40 or later.",
      "Upgrade Gateway to 3.5.22.40 or later.",
      "Upgrade Edge Gateway for Windows to 3.5.22.40 or later.",
      "Upgrade HMI (SL) to 3.5.22.40 or later.",
      "Upgrade OPC DA Server SL to 3.5.22.40 or later.",
      "Upgrade PLCHandler to 3.5.22.40 or later.",
      "Upgrade Runtime Toolkit to 3.5.22.40 or later.",
      "Upgrade Edge Gateway for Linux to 4.23.0.0 or later."
    ]
  },
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}