  "id": "CVE-2026-67367",
  "url": "https://poc.griffinguard.io/cve/CVE-2026-67367",
  "published_at": "2026-09-08T08:11:36.311Z",
  "vendor": "Siemens",
  "product": "SIMOVE Fleetmanager V3.1",
  "cvss": {
    "score": 9.2,
    "source": "cna",
    "vector": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": null,
  "description": "A vulnerability has been identified in SIMOVE Fleetmanager V3.1 (All versions \u003c V3.1.13), SIMOVE Fleetmanager V3.2 (All versions \u003c V3.2.4), SIMOVE Fleetmanager V3.3 (All versions \u003c V3.3.2), SIMOVE Fleetmanager V4.0 (All versions \u003c V4.0.1), SIPLANT V1.7 (All versions), SIPLANT V2.2 (All versions), SIPLANT V3.0 (All versions), SIPLANT V3.1 (All versions \u003c V3.1.4). Affected devices do not properly validate and neutralize directory traversal sequences in the file-serving endpoint of the embedded HTTP server. This could allow an unauthenticated remote attacker to read arbitrary files from the underlying operating system without any credentials, potentially exposing sensitive data such as credential stores, private keys, and configuration secrets.",
  "cwe": "CWE-23",
  "cvss_by_source": {
    "cna": 9.2
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "Siemens",
        "product": "SIMOVE Fleetmanager V3.1",
        "ranges": [
          "\u003c V3.1.13"
        ],
        "fixed_in": [
          "V3.1.13"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIMOVE Fleetmanager V3.2",
        "ranges": [
          "\u003c V3.2.4"
        ],
        "fixed_in": [
          "V3.2.4"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIMOVE Fleetmanager V3.3",
        "ranges": [
          "\u003c V3.3.2"
        ],
        "fixed_in": [
          "V3.3.2"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIMOVE Fleetmanager V4.0",
        "ranges": [
          "\u003c V4.0.1"
        ],
        "fixed_in": [
          "V4.0.1"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIPLANT V1.7",
        "ranges": [
          "\u003c *"
        ],
        "fixed_in": [
          "*"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIPLANT V2.2",
        "ranges": [
          "\u003c *"
        ],
        "fixed_in": [
          "*"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIPLANT V3.0",
        "ranges": [
          "\u003c *"
        ],
        "fixed_in": [
          "*"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIPLANT V3.1",
        "ranges": [
          "\u003c V3.1.4"
        ],
        "fixed_in": [
          "V3.1.4"
        ]
      }
    ],
    "upgrade": [
      "Upgrade SIMOVE Fleetmanager V3.1 to V3.1.13 or later.",
      "Upgrade SIMOVE Fleetmanager V3.2 to V3.2.4 or later.",
      "Upgrade SIMOVE Fleetmanager V3.3 to V3.3.2 or later.",
      "Upgrade SIMOVE Fleetmanager V4.0 to V4.0.1 or later.",
      "Upgrade SIPLANT V1.7 to * or later.",
      "Upgrade SIPLANT V2.2 to * or later.",
      "Upgrade SIPLANT V3.0 to * or later.",
      "Upgrade SIPLANT V3.1 to V3.1.4 or later."
    ]
  },
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}