  "id": "CVE-2026-50058",
  "url": "https://poc.griffinguard.io/cve/CVE-2026-50058",
  "published_at": "2026-08-11T12:20:13.806Z",
  "vendor": "Siemens",
  "product": "Solid Edge SE2025",
  "cvss": {
    "score": 7.8,
    "source": "cna",
    "vector": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": null,
  "description": "A vulnerability has been identified in Solid Edge SE2025 (All versions \u003c V225.0 Update 15), Solid Edge SE2026 (All versions \u003c V226.0 Update 7). The affected applications contains an out of bounds read vulnerability while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.",
  "cwe": "CWE-125",
  "cpes": [
    "cpe:2.3:a:siemens:solid_edge_se2025:225.0:-:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0001:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0002:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0003:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0004:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0005:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0006:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0007:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0008:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0009:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0010:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0011:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0012:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0013:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0014:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2026:226.0:-:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2026:226.0:update_1:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2026:226.0:update_2:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2026:226.0:update_3:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2026:226.0:update_4:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2026:226.0:update_5:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:solid_edge_se2026:226.0:update_6:*:*:*:*:*:*"
  ],
  "cvss_by_source": {
    "cna": 7.8
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "Siemens",
        "product": "Solid Edge SE2025",
        "ranges": [
          "\u003c V225.0 Update 15"
        ],
        "fixed_in": [
          "V225.0 Update 15"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "Solid Edge SE2026",
        "ranges": [
          "\u003c V226.0 Update 7"
        ],
        "fixed_in": [
          "V226.0 Update 7"
        ]
      }
    ],
    "upgrade": [
      "Upgrade Solid Edge SE2025 to V225.0 Update 15 or later.",
      "Upgrade Solid Edge SE2026 to V226.0 Update 7 or later."
    ]
  },
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}