  "id": "CVE-2026-41551",
  "url": "https://poc.griffinguard.io/cve/CVE-2026-41551",
  "published_at": "2026-05-12T08:21:18.261Z",
  "vendor": "Siemens",
  "product": "ROS#",
  "cvss": {
    "score": 9.3,
    "source": "cna",
    "vector": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": {
    "created_at": "2026-08-25T05:12:40Z",
    "first_seen_at": "2026-11-14T11:25:11.578Z",
    "days_after_publication": 104.9,
    "repo": "selecthch/CVE-2026-41551",
    "source": "github"
  },
  "poc_repo_count": 1,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": null,
  "description": "A vulnerability has been identified in ROS# (All versions \u003c V2.2.2). Affected versions contain a path traversal vulnerability because user input is not properly sanitized.\r\nThis could allow a remote attacker to access arbitrary files on the device.",
  "cwe": "CWE-23",
  "cvss_by_source": {
    "cna": 9.3
  },
  "repos": [
    {
      "repo": "selecthch/CVE-2026-41551",
      "url": "https://github.com/selecthch/CVE-2026-41551",
      "created_at": "2026-08-25T05:12:40Z",
      "first_seen_at": "2026-11-14T11:25:11.578Z",
      "stars": 1,
      "is_poc": "yes",
      "kind": "exploit",
      "suspicion_score": 40,
      "suspicious": false,
      "suspicion_reasons": [
        "contains archives (ros2_ws.zip)",
        "no network code found (normal for a local exploit)"
      ],
      "status": "analyzed",
      "owner_created_at": "2019-06-29T08:39:06Z"
    }
  ],
  "remediation": {
    "affected": [
      {
        "vendor": "Siemens",
        "product": "ROS#",
        "ranges": [
          "\u003c V2.2.2"
        ],
        "fixed_in": [
          "V2.2.2"
        ]
      }
    ],
    "upgrade": [
      "Upgrade ROS# to V2.2.2 or later."
    ]
  },
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}