  "id": "CVE-2026-36540",
  "url": "https://poc.griffinguard.io/cve/CVE-2026-36540",
  "published_at": "2026-05-27T00:00:00Z",
  "cvss": {
    "score": 7.3,
    "source": "cisa-adp",
    "vector": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": null,
  "description": "Netis AC1200 Router NC21 V4.0.1.4296 is vulnerable to unauthenticated command injection via the /cgi-bin/skk_set.cgi endpoint. The password and new_pwd_confirm POST parameters are passed directly to the underlying OS shell without sanitization. An attacker can inject arbitrary shell commands by wrapping them in backticks (`) and encoding them in base64. Because the endpoint requires no authentication, any device on the LAN can achieve full Remote Code Execution on the router's operating system with a single HTTP POST request.",
  "cwe": "CWE-77",
  "cvss_by_source": {
    "cisa-adp": 7.3
  },
  "repos": [],
  "remediation": null,
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}