  "id": "CVE-2026-3509",
  "url": "https://poc.griffinguard.io/cve/CVE-2026-3509",
  "published_at": "2026-03-24T07:42:33.82Z",
  "title": "CODESYS Control Audit Log Format String DoS",
  "vendor": "CODESYS",
  "product": "CODESYS Control RTE (SL)",
  "cvss": {
    "score": 7.5,
    "source": "cna",
    "vector": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": null,
  "description": "An unauthenticated remote attacker may be able to control the format string of messages processed by the Audit Log of the CODESYS Control runtime system, potentially resulting in a denial‑of‑service (DoS) condition.",
  "cwe": "CWE-134",
  "cvss_by_source": {
    "cna": 7.5
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "CODESYS",
        "product": "CODESYS Control RTE (SL)",
        "ranges": [
          "\u003e= 3.5.17.0, \u003c 3.5.22.0"
        ],
        "fixed_in": [
          "3.5.22.0"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "CODESYS Control RTE (for Beckhoff CX) SL",
        "ranges": [
          "\u003e= 3.5.17.0, \u003c 3.5.22.0"
        ],
        "fixed_in": [
          "3.5.22.0"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "CODESYS Control Win (SL)",
        "ranges": [
          "\u003e= 3.5.17.0, \u003c 3.5.22.0"
        ],
        "fixed_in": [
          "3.5.22.0"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "CODESYS Runtime Toolkit",
        "ranges": [
          "\u003e= 3.5.17.0, \u003c 3.5.22.0"
        ],
        "fixed_in": [
          "3.5.22.0"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "CODESYS Control for BeagleBone SL",
        "ranges": [
          "\u003e= 4.1.0.0, \u003c 4.21.0.0"
        ],
        "fixed_in": [
          "4.21.0.0"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "CODESYS Control for emPC-A/iMX6 SL",
        "ranges": [
          "\u003e= 4.1.0.0, \u003c 4.21.0.0"
        ],
        "fixed_in": [
          "4.21.0.0"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "CODESYS Control for IOT2000 SL",
        "ranges": [
          "\u003e= 4.1.0.0, \u003c 4.21.0.0"
        ],
        "fixed_in": [
          "4.21.0.0"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "CODESYS Control for Linux ARM SL",
        "ranges": [
          "\u003e= 4.1.0.0, \u003c 4.21.0.0"
        ],
        "fixed_in": [
          "4.21.0.0"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "CODESYS Control for Linux SL",
        "ranges": [
          "\u003e= 4.1.0.0, \u003c 4.21.0.0"
        ],
        "fixed_in": [
          "4.21.0.0"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "CODESYS Control for PFC100 SL",
        "ranges": [
          "\u003e= 4.1.0.0, \u003c 4.21.0.0"
        ],
        "fixed_in": [
          "4.21.0.0"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "CODESYS Control for PFC200 SL",
        "ranges": [
          "\u003e= 4.1.0.0, \u003c 4.21.0.0"
        ],
        "fixed_in": [
          "4.21.0.0"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "CODESYS Control for PLCnext SL",
        "ranges": [
          "\u003e= 4.1.0.0, \u003c 4.21.0.0"
        ],
        "fixed_in": [
          "4.21.0.0"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "CODESYS Control for Raspberry Pi SL",
        "ranges": [
          "\u003e= 4.1.0.0, \u003c 4.21.0.0"
        ],
        "fixed_in": [
          "4.21.0.0"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "CODESYS Control for WAGO Touch Panels 600 SL",
        "ranges": [
          "\u003e= 4.1.0.0, \u003c 4.21.0.0"
        ],
        "fixed_in": [
          "4.21.0.0"
        ]
      },
      {
        "vendor": "CODESYS",
        "product": "CODESYS Virtual Control SL",
        "ranges": [
          "\u003e= 4.1.0.0, \u003c 4.21.0.0"
        ],
        "fixed_in": [
          "4.21.0.0"
        ]
      }
    ],
    "upgrade": [
      "Upgrade CODESYS Control RTE (SL) to 3.5.22.0 or later.",
      "Upgrade CODESYS Control RTE (for Beckhoff CX) SL to 3.5.22.0 or later.",
      "Upgrade CODESYS Control Win (SL) to 3.5.22.0 or later.",
      "Upgrade CODESYS Runtime Toolkit to 3.5.22.0 or later.",
      "Upgrade CODESYS Control for BeagleBone SL to 4.21.0.0 or later.",
      "Upgrade CODESYS Control for emPC-A/iMX6 SL to 4.21.0.0 or later.",
      "Upgrade CODESYS Control for IOT2000 SL to 4.21.0.0 or later.",
      "Upgrade CODESYS Control for Linux ARM SL to 4.21.0.0 or later.",
      "Upgrade CODESYS Control for Linux SL to 4.21.0.0 or later.",
      "Upgrade CODESYS Control for PFC100 SL to 4.21.0.0 or later.",
      "Upgrade CODESYS Control for PFC200 SL to 4.21.0.0 or later.",
      "Upgrade CODESYS Control for PLCnext SL to 4.21.0.0 or later.",
      "Upgrade CODESYS Control for Raspberry Pi SL to 4.21.0.0 or later.",
      "Upgrade CODESYS Control for WAGO Touch Panels 600 SL to 4.21.0.0 or later.",
      "Upgrade CODESYS Virtual Control SL to 4.21.0.0 or later."
    ]
  },
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}