  "id": "CVE-2026-16835",
  "url": "https://poc.griffinguard.io/cve/CVE-2026-16835",
  "published_at": "2026-08-19T18:52:26.786Z",
  "title": "Power System Improper Certificate Validation",
  "vendor": "IBM",
  "product": "Power Systems Firmware",
  "cvss": {
    "score": 9.6,
    "source": "cna",
    "vector": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": {
    "category": "Device firmware",
    "confidence": "medium",
    "reason": "hardware or firmware CPE: ibm power_system_e1080_\\(9080-hex\\)_firmware"
  },
  "description": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An unauthenticated attacker on the management network can bypass authentication and perform any administrative operation on the managed system, including control of partition power state, configuration, and console access across all hosted partitions, resulting in a confidentiality, integrity, and availability impact to the managed system.",
  "cwe": "CWE-295",
  "cpes": [
    "cpe:2.3:o:ibm:power_system_e1080_\\(9080-hex\\)_firmware:*:*:*:*:*:*:*:*",
    "cpe:2.3:o:ibm:power_system_e1180_\\(9080-heu\\)_firmware:*:*:*:*:*:*:*:*",
    "cpe:2.3:o:ibm:power_system_e1180_\\(9080-heu\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
    "cpe:2.3:o:ibm:power_system_e950_\\(9040-mr9\\)_firmware:*:*:*:*:*:*:*:*",
    "cpe:2.3:o:ibm:power_system_e980_\\(9080-m9s\\)_firmware:*:*:*:*:*:*:*:*",
    "cpe:2.3:o:ibm:power_system_h922_\\(9223-22s\\)_firmware:*:*:*:*:*:*:*:*",
    "cpe:2.3:o:ibm:power_system_h924_\\(9223-42s\\)_firmware:*:*:*:*:*:*:*:*",
    "cpe:2.3:o:ibm:power_system_s914_\\(9009-41g\\)_firmware:*:*:*:*:*:*:*:*",
    "cpe:2.3:o:ibm:power_system_s922_\\(9009-22g\\)_firmware:*:*:*:*:*:*:*:*",
    "cpe:2.3:o:ibm:power_system_s924_\\(9009-42g\\)_firmware:*:*:*:*:*:*:*:*"
  ],
  "cvss_by_source": {
    "cna": 9.6
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "IBM",
        "product": "Power Systems Firmware",
        "ranges": [
          "FW1120.00",
          "\u003e= FW1110.00, \u003c= FW1110.30",
          "\u003e= FW1060.00, \u003c= FW1060.80",
          "\u003e= FW950.00, \u003c= FW950.H2"
        ],
        "fixed_in": null
      }
    ],
    "solutions": [
      "IBM strongly recommends customers with the products below install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability as soon as possible.\n\n\n\nPower 11\n1) IBM Power System E1180 (9080-HEU)\n\n\n\nIBM strongly recommends customers with the products below install FW1060.81(1060_184) or newer to remediate this vulnerability as soon as possible.\n\n\n\nPower 10\n1) IBM Power System E1080 (9080-HEX)\n\n\n\nIBM strongly recommends customers with the products below install FW950.H3(950_230) or newer to remediate this vulnerability as soon as possible.\n\n\n\nPower 9\n1) IBM Power System S922 (9009-22G)\n2) IBM Power System H922 (9223-22S)\n3) IBM Power System S914 (9009-41G)\n4) IBM Power System S924 (9009-42G)\n5) IBM Power System H924 (9223-42S)\n6) IBM Power System E950 (9040-MR9)\n7) IBM Power System E980 (9080-M9S)\n\n\n\nThe images mentioned above can be located at IBM Fix Central :  https://www.ibm.com/support/fixcentral/"
    ],
    "workarounds": [
      "Protect access to the FSP's network interface."
    ],
    "references": [
      {
        "kind": "Vendor advisory",
        "url": "https://www.ibm.com/support/pages/node/7283894"
      }
    ]
  },
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}