  "id": "CVE-2026-105281",
  "url": "https://poc.griffinguard.io/cve/CVE-2026-105281",
  "published_at": "2026-10-09T13:49:06.352Z",
  "title": "Grid Protection Alliance openPDC and openHistorian Missing Authentication for Critical Function",
  "vendor": "Grid Protection Alliance",
  "product": "openPDC",
  "cvss": {
    "score": 8.7,
    "source": "cna",
    "vector": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": null,
  "description": "The internal data publisher on openPDC accepts network connections without authentication in its default configuration. An unauthenticated network attacker can connect to this interface and retrieve the complete device and measurement topology of the system.",
  "cwe": "CWE-306",
  "cvss_by_source": {
    "cna": 8.7
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "Grid Protection Alliance",
        "product": "openPDC",
        "ranges": [
          "\u003c 2.9.477",
          "\u003c 2.9.482"
        ],
        "fixed_in": [
          "2.9.477",
          "2.9.482"
        ]
      },
      {
        "vendor": "Grid Protection Alliance",
        "product": "openPDC (Docker image)",
        "ranges": [
          "\u003c 2.9.477",
          "\u003c 2.9.482"
        ],
        "fixed_in": [
          "2.9.477",
          "2.9.482"
        ]
      },
      {
        "vendor": "Grid Protection Alliance",
        "product": "openHistorian",
        "ranges": [
          "\u003c 2.8.580",
          "\u003c 2.8.585"
        ],
        "fixed_in": [
          "2.8.580",
          "2.8.585"
        ]
      }
    ],
    "solutions": [
      "Grid Protection Alliance updated the default configuration to bind this interface to the local loopback address only. This change applies to new installations; existing installations upgraded from an earlier version retain their prior configuration and will not receive the new default automatically. Operators should verify their configuration explicitly and update the interface binding if it is still set to accept connections on all interfaces."
    ],
    "upgrade": [
      "Upgrade openPDC to 2.9.477 or 2.9.482 or later.",
      "Upgrade openPDC (Docker image) to 2.9.477 or 2.9.482 or later.",
      "Upgrade openHistorian to 2.8.580 or 2.8.585 or later."
    ],
    "workarounds": [
      "Grid Protection Alliance does not recommend production use of published Docker images in any case. The fix for this vulnerability has not been published to the Docker image."
    ]
  },
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}