  "id": "CVE-2026-101153",
  "url": "https://poc.griffinguard.io/cve/CVE-2026-101153",
  "published_at": "2026-10-06T19:38:07.896Z",
  "title": "Security Advisory 0188",
  "vendor": "Arista Networks",
  "product": "CloudVision Portal",
  "cvss": {
    "score": 8,
    "source": "cna",
    "vector": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": null,
  "description": "On affected versions of CloudVision Portal (on-premises) or CloudVision Sensor, a path traversal vulnerability exists. An authenticated user with sufficient high privileges could exploit this to extract unintended data from the Sensor.",
  "cwe": "CWE-22",
  "cvss_by_source": {
    "cna": 8
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "Arista Networks",
        "product": "CloudVision Portal",
        "ranges": [
          "2026.2.0",
          "\u003e= 2026.1.0, \u003c= 2026.1.2",
          "\u003e= 2025.3.0, \u003c= 2025.3.3",
          "\u003e= 2025.2.0, \u003c= 2025.2.3",
          "\u003e= 2025.1.0, \u003c= 2025.1.4",
          "\u003e= 2024.3.0, \u003c= 2024.3.3"
        ],
        "fixed_in": null
      },
      {
        "vendor": "Arista Networks",
        "product": "CloudVision Sensor",
        "ranges": [
          "\u003e= 1.4.0, \u003c= 1.4.2",
          "\u003e= 1.3.0, \u003c= 1.3.1",
          "\u003e= 1.0.0, \u003c 1.3.0"
        ],
        "fixed_in": [
          "1.3.0"
        ]
      }
    ],
    "solutions": [
      "CVE-2026-101153 has been fixed in the following releases:\n\nCloudVision Portal:\n- 2026.2.1 and later releases in the 2026.2.x train\n- 2026.1.3 and later releases in the 2026.1.x train\n\nCloudVision Sensor:\n- 1.4.3 and later releases in the 1.4.x train"
    ],
    "upgrade": [
      "Upgrade CloudVision Sensor to 1.3.0 or later."
    ],
    "workarounds": [
      "There is no reliable mitigation other than stopping the sensor component completely, which would prevent all functionality dependent on it from working. To stop the sensor, execute the following command on the CloudVision or Sensor VM:\n\n# Stop sensor completely:\ncvpi stop sensor\n\nTo undo this and to start the sensor again use:\n\n# Start sensor:\ncvpi start sensor"
    ],
    "references": [
      {
        "kind": "Vendor advisory",
        "url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24804-security-advisory-0188"
      }
    ]
  },
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}