  "id": "CVE-2025-9935",
  "url": "https://poc.griffinguard.io/cve/CVE-2025-9935",
  "published_at": "2025-09-03T23:02:09.84Z",
  "title": "TOTOLINK N600R cstecgi.cgi sub_4159F8 command injection",
  "vendor": "TOTOLINK",
  "product": "N600R",
  "cvss": {
    "score": 9.8,
    "source": "nvd",
    "vector": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": {
    "category": "Router / network device",
    "confidence": "high",
    "reason": "known edge product: TOTOLINK N600R TOTOLINK N600R cstecgi.cgi sub_4159F8 command"
  },
  "description": "A vulnerability was determined in TOTOLINK N600R 4.3.0cu.7866_B20220506. This vulnerability affects the function sub_4159F8 of the file /web_cste/cgi-bin/cstecgi.cgi. Executing manipulation can lead to command injection. The attack can be executed remotely. The exploit has been publicly disclosed and may be utilized.",
  "cwe": "CWE-77",
  "cpes": [
    "cpe:2.3:o:totolink:n600r_firmware:4.3.0cu.7866_b20220506:*:*:*:*:*:*:*"
  ],
  "cvss_by_source": {
    "cna": 7.5,
    "nvd": 9.8
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "TOTOLINK",
        "product": "N600R",
        "ranges": [
          "4.3.0cu.7866_B20220506"
        ],
        "fixed_in": null
      }
    ]
  },
  "exploit_refs": [
    {
      "url": "https://github.com/mono7s/TOTOLINK/blob/main/N600R/TOTOLINK%20N600R%20Unauthorized_Command_Injection.md",
      "source": "pocindex",
      "title": "",
      "published_at": null,
      "first_seen_at": "2026-11-14T11:25:11.578Z"
    }
  ],
  "hunt_profile": [],
  "rules": []
}