  "id": "CVE-2025-41770",
  "url": "https://poc.griffinguard.io/cve/CVE-2025-41770",
  "published_at": "2026-08-12T08:06:26.952Z",
  "title": "Unauthenticated Denial of Service",
  "vendor": "Phoenix Contact",
  "product": "AXC F 1152",
  "cvss": {
    "score": 8.7,
    "source": "cna",
    "vector": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": null,
  "description": "An unauthenticated denial-of-service vulnerability in the device's PLCnext Engineer communication interface allow an remote attacker to interrupt access via the client application. Successful exploitation prevents communication until the PLCnext service is manually restarted.",
  "cwe": "CWE-770",
  "cvss_by_source": {
    "cna": 8.7
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "Phoenix Contact",
        "product": "AXC F 1152",
        "ranges": [
          "\u003e= 2019.0.4, \u003c 2026.0.3"
        ],
        "fixed_in": [
          "2026.0.3"
        ]
      },
      {
        "vendor": "Phoenix Contact",
        "product": "AXC F 1252",
        "ranges": [
          "\u003e= 2019.0.4, \u003c 2026.0.3"
        ],
        "fixed_in": [
          "2026.0.3"
        ]
      },
      {
        "vendor": "Phoenix Contact",
        "product": "AXC F 2000 EA",
        "ranges": [
          "\u003e= 2019.0.4, \u003c 2026.0.3"
        ],
        "fixed_in": [
          "2026.0.3"
        ]
      },
      {
        "vendor": "Phoenix Contact",
        "product": "AXC F 2152",
        "ranges": [
          "\u003e= 2019.0.4, \u003c 2026.0.3"
        ],
        "fixed_in": [
          "2026.0.3"
        ]
      },
      {
        "vendor": "Phoenix Contact",
        "product": "AXC F 3152",
        "ranges": [
          "\u003e= 2019.0.4, \u003c 2026.0.3"
        ],
        "fixed_in": [
          "2026.0.3"
        ]
      },
      {
        "vendor": "Phoenix Contact",
        "product": "BPC 9102S",
        "ranges": [
          "\u003e= 2019.0.4, \u003c 2026.0.3"
        ],
        "fixed_in": [
          "2026.0.3"
        ]
      },
      {
        "vendor": "Phoenix Contact",
        "product": "BPC 9202S",
        "ranges": [
          "\u003e= 2019.0.4, \u003c 2026.0.3"
        ],
        "fixed_in": [
          "2026.0.3"
        ]
      },
      {
        "vendor": "Phoenix Contact",
        "product": "RFC 4072R",
        "ranges": [
          "\u003e= 2019.0.4, \u003c 2026.0.3"
        ],
        "fixed_in": [
          "2026.0.3"
        ]
      },
      {
        "vendor": "Phoenix Contact",
        "product": "RFC 4072S",
        "ranges": [
          "\u003e= 2019.0.4, \u003c 2026.0.3"
        ],
        "fixed_in": [
          "2026.0.3"
        ]
      },
      {
        "vendor": "Phoenix Contact",
        "product": "VL3 UPC 2440 EDGE",
        "ranges": [
          "\u003e= 2019.0.4, \u003c 2026.0.3"
        ],
        "fixed_in": [
          "2026.0.3"
        ]
      },
      {
        "vendor": "Phoenix Contact",
        "product": "VPLCNEXT CONTROL 1000",
        "ranges": [
          "\u003e= 2019.0.4, \u003c 2026.0.3"
        ],
        "fixed_in": [
          "2026.0.3"
        ]
      },
      {
        "vendor": "Phoenix Contact",
        "product": "VPLCNEXT CONTROL 2000",
        "ranges": [
          "\u003e= 2019.0.4, \u003c 2026.0.3"
        ],
        "fixed_in": [
          "2026.0.3"
        ]
      },
      {
        "vendor": "Phoenix Contact",
        "product": "VPLCNEXT CONTROL 3000",
        "ranges": [
          "\u003e= 2019.0.4, \u003c 2026.0.3"
        ],
        "fixed_in": [
          "2026.0.3"
        ]
      },
      {
        "vendor": "Phoenix Contact",
        "product": "VPLCNEXT CONTROL 500",
        "ranges": [
          "\u003e= 2019.0.4, \u003c 2026.0.3"
        ],
        "fixed_in": [
          "2026.0.3"
        ]
      },
      {
        "vendor": "Phoenix Contact",
        "product": "Catan C1",
        "ranges": [
          "\u003e= 2019.0.4, \u003c 2026.0.3"
        ],
        "fixed_in": [
          "2026.0.3"
        ]
      },
      {
        "vendor": "Phoenix Contact",
        "product": "EPC 1502",
        "ranges": [
          "\u003e= 2019.0.4, \u003c 2026.0.3"
        ],
        "fixed_in": [
          "2026.0.3"
        ]
      },
      {
        "vendor": "Phoenix Contact",
        "product": "EPC 1522",
        "ranges": [
          "\u003e= 2019.0.4, \u003c 2026.0.3"
        ],
        "fixed_in": [
          "2026.0.3"
        ]
      }
    ],
    "upgrade": [
      "Upgrade AXC F 1152 to 2026.0.3 or later.",
      "Upgrade AXC F 1252 to 2026.0.3 or later.",
      "Upgrade AXC F 2000 EA to 2026.0.3 or later.",
      "Upgrade AXC F 2152 to 2026.0.3 or later.",
      "Upgrade AXC F 3152 to 2026.0.3 or later.",
      "Upgrade BPC 9102S to 2026.0.3 or later.",
      "Upgrade BPC 9202S to 2026.0.3 or later.",
      "Upgrade RFC 4072R to 2026.0.3 or later.",
      "Upgrade RFC 4072S to 2026.0.3 or later.",
      "Upgrade VL3 UPC 2440 EDGE to 2026.0.3 or later.",
      "Upgrade VPLCNEXT CONTROL 1000 to 2026.0.3 or later.",
      "Upgrade VPLCNEXT CONTROL 2000 to 2026.0.3 or later.",
      "Upgrade VPLCNEXT CONTROL 3000 to 2026.0.3 or later.",
      "Upgrade VPLCNEXT CONTROL 500 to 2026.0.3 or later.",
      "Upgrade Catan C1 to 2026.0.3 or later.",
      "Upgrade EPC 1502 to 2026.0.3 or later.",
      "Upgrade EPC 1522 to 2026.0.3 or later."
    ]
  },