  "id": "CVE-2025-40944",
  "url": "https://poc.griffinguard.io/cve/CVE-2025-40944",
  "published_at": "2026-01-13T09:44:05.792Z",
  "vendor": "Siemens",
  "product": "SIMATIC ET 200AL IM 157-1 PN",
  "cvss": {
    "score": 8.7,
    "source": "cna",
    "vector": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": null,
  "description": "A vulnerability has been identified in SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0) (All versions), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0) (All versions \u003e= V4.2.0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0) (All versions), SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) (All versions \u003c V1.3), SIMATIC ET 200SP IM 155-6 PN R1 (6ES7155-6AU00-0HM0) (All versions \u003c V6.0.1), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0) (All versions \u003e= V4.2.0 \u003c V4.2.5), SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0) (All versions \u003c V4.2.2), SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0) (All versions), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0) (All versions \u003c V6.0.0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0) (All versions \u003e= V4.2.0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0) (All versions \u003e= V4.2.0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0) (All versions \u003e= V4.2.0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0) (All versions \u003e= V4.2.0 \u003c V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0) (All versions \u003e= V4.2.0 \u003c V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0) (All versions \u003e= V4.2.0 \u003c V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0) (All versions \u003e= V4.2.0 \u003c V4.2.5), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0) (All versions \u003c V6.0.0). Affected devices do not properly handle S7 protocol session disconnect requests. When receiving a valid S7 protocol Disconnect Request (COTP DR TPDU) on TCP port 102, the devices enter an improper session state.\r\n\r\nThis could allow an attacker to cause the device to become unresponsive, leading to a denial-of-service condition that requires a power cycle to restore normal operation.",
  "cwe": "CWE-400",
  "cvss_by_source": {
    "cna": 8.7
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "Siemens",
        "product": "SIMATIC ET 200AL IM 157-1 PN",
        "ranges": [
          "\u003c *"
        ],
        "fixed_in": [
          "*"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIMATIC ET 200MP IM 155-5 PN HF",
        "ranges": [
          "\u003e= V4.2.0, \u003c *"
        ],
        "fixed_in": [
          "*"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIMATIC ET 200SP IM 155-6 MF HF",
        "ranges": [
          "\u003c *"
        ],
        "fixed_in": [
          "*"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)",
        "ranges": [
          "\u003c V1.3"
        ],
        "fixed_in": [
          "V1.3"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIMATIC ET 200SP IM 155-6 PN R1",
        "ranges": [
          "\u003c V6.0.1"
        ],
        "fixed_in": [
          "V6.0.1"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIMATIC ET 200SP IM 155-6 PN/2 HF",
        "ranges": [
          "\u003e= V4.2.0, \u003c V4.2.5"
        ],
        "fixed_in": [
          "V4.2.5"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIMATIC ET 200SP IM 155-6 PN/3 HF",
        "ranges": [
          "\u003c V4.2.2"
        ],
        "fixed_in": [
          "V4.2.2"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIMATIC PN/MF Coupler",
        "ranges": [
          "\u003c *"
        ],
        "fixed_in": [
          "*"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIMATIC PN/PN Coupler",
        "ranges": [
          "\u003c V6.0.0"
        ],
        "fixed_in": [
          "V6.0.0"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIPLUS ET 200MP IM 155-5 PN HF",
        "ranges": [
          "\u003e= V4.2.0, \u003c *"
        ],
        "fixed_in": [
          "*"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIPLUS ET 200MP IM 155-5 PN HF",
        "ranges": [
          "\u003e= V4.2.0, \u003c *"
        ],
        "fixed_in": [
          "*"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
        "ranges": [
          "\u003e= V4.2.0, \u003c *"
        ],
        "fixed_in": [
          "*"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIPLUS ET 200SP IM 155-6 PN HF",
        "ranges": [
          "\u003e= V4.2.0, \u003c V4.2.5"
        ],
        "fixed_in": [
          "V4.2.5"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIPLUS ET 200SP IM 155-6 PN HF",
        "ranges": [
          "\u003e= V4.2.0, \u003c V4.2.5"
        ],
        "fixed_in": [
          "V4.2.5"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
        "ranges": [
          "\u003e= V4.2.0, \u003c V4.2.5"
        ],
        "fixed_in": [
          "V4.2.5"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL",
        "ranges": [
          "\u003e= V4.2.0, \u003c V4.2.5"
        ],
        "fixed_in": [
          "V4.2.5"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIPLUS NET PN/PN Coupler",
        "ranges": [
          "\u003c V6.0.0"
        ],
        "fixed_in": [
          "V6.0.0"
        ]
      }
    ],
    "upgrade": [
      "Upgrade SIMATIC ET 200AL IM 157-1 PN to * or later.",
      "Upgrade SIMATIC ET 200MP IM 155-5 PN HF to * or later.",
      "Upgrade SIMATIC ET 200SP IM 155-6 MF HF to * or later.",
      "Upgrade SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) to V1.3 or later.",
      "Upgrade SIMATIC ET 200SP IM 155-6 PN R1 to V6.0.1 or later.",
      "Upgrade SIMATIC ET 200SP IM 155-6 PN/2 HF to V4.2.5 or later.",
      "Upgrade SIMATIC ET 200SP IM 155-6 PN/3 HF to V4.2.2 or later.",
      "Upgrade SIMATIC PN/MF Coupler to * or later.",
      "Upgrade SIMATIC PN/PN Coupler to V6.0.0 or later.",
      "Upgrade SIPLUS ET 200MP IM 155-5 PN HF to * or later.",
      "Upgrade SIPLUS ET 200MP IM 155-5 PN HF to * or later.",
      "Upgrade SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL to * or later.",
      "Upgrade SIPLUS ET 200SP IM 155-6 PN HF to V4.2.5 or later.",
      "Upgrade SIPLUS ET 200SP IM 155-6 PN HF to V4.2.5 or later.",
      "Upgrade SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL to V4.2.5 or later.",
      "Upgrade SIPLUS ET 200SP IM 155-6 PN HF TX RAIL to V4.2.5 or later.",
      "Upgrade SIPLUS NET PN/PN Coupler to V6.0.0 or later."
    ]
  },
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}