  "id": "CVE-2025-40800",
  "url": "https://poc.griffinguard.io/cve/CVE-2025-40800",
  "published_at": "2025-12-09T10:44:23.488Z",
  "vendor": "Siemens",
  "product": "COMOS V10.6",
  "cvss": {
    "score": 9.1,
    "source": "cna",
    "vector": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": null,
  "description": "A vulnerability has been identified in COMOS V10.6 (All versions \u003c V10.6.1), COMOS V10.6 (All versions \u003c V10.6.1), NX V2412 (All versions \u003c V2412.8700), NX V2506 (All versions \u003c V2506.6000), Simcenter 3D (All versions \u003c V2506.6000), Simcenter Femap (All versions \u003c V2506.0002), Solid Edge SE2025 (All versions \u003c V225.0 Update 10), Solid Edge SE2026 (All versions \u003c V226.0 Update 1). The IAM client in affected products is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.",
  "cwe": "CWE-295",
  "cvss_by_source": {
    "cna": 9.1
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "Siemens",
        "product": "COMOS V10.6",
        "ranges": [
          "\u003c V10.6.1"
        ],
        "fixed_in": [
          "V10.6.1"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "COMOS V10.6",
        "ranges": [
          "\u003c V10.6.1"
        ],
        "fixed_in": [
          "V10.6.1"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "NX V2412",
        "ranges": [
          "\u003c V2412.8700"
        ],
        "fixed_in": [
          "V2412.8700"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "NX V2506",
        "ranges": [
          "\u003c V2506.6000"
        ],
        "fixed_in": [
          "V2506.6000"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "Simcenter 3D",
        "ranges": [
          "\u003c V2506.6000"
        ],
        "fixed_in": [
          "V2506.6000"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "Simcenter Femap",
        "ranges": [
          "\u003c V2506.0002"
        ],
        "fixed_in": [
          "V2506.0002"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "Solid Edge SE2025",
        "ranges": [
          "\u003c V225.0 Update 10"
        ],
        "fixed_in": [
          "V225.0 Update 10"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "Solid Edge SE2026",
        "ranges": [
          "\u003c V226.0 Update 1"
        ],
        "fixed_in": [
          "V226.0 Update 1"
        ]
      }
    ],
    "upgrade": [
      "Upgrade COMOS V10.6 to V10.6.1 or later.",
      "Upgrade COMOS V10.6 to V10.6.1 or later.",
      "Upgrade NX V2412 to V2412.8700 or later.",
      "Upgrade NX V2506 to V2506.6000 or later.",
      "Upgrade Simcenter 3D to V2506.6000 or later.",
      "Upgrade Simcenter Femap to V2506.0002 or later.",
      "Upgrade Solid Edge SE2025 to V225.0 Update 10 or later.",
      "Upgrade Solid Edge SE2026 to V226.0 Update 1 or later."
    ]
  },
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}