  "id": "CVE-2025-40594",
  "url": "https://poc.griffinguard.io/cve/CVE-2025-40594",
  "published_at": "2025-09-09T08:47:57.771Z",
  "vendor": "Siemens",
  "product": "SINAMICS G220 V6.4",
  "cvss": {
    "score": 9.8,
    "source": "nvd",
    "vector": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": {
    "category": "Device firmware",
    "confidence": "medium",
    "reason": "hardware or firmware CPE: siemens sinamics_g220_firmware"
  },
  "description": "A vulnerability has been identified in SINAMICS G220 V6.4 (All versions \u003c V6.4 HF2), SINAMICS S200 V6.4 (All versions \u003c V6.4 HF7), SINAMICS S210 V6.4 (All versions \u003c V6.4 HF2). The affected devices allow a factory reset to be executed without the required privileges due to improper privilege management as well as manipulation of configuration data because of leaked privileges of previous sessions. This could allow an unauthorized attacker to escalate their privileges.",
  "cwe": "CWE-269",
  "cpes": [
    "cpe:2.3:o:siemens:sinamics_g220_firmware:6.4:-:*:*:*:*:*:*",
    "cpe:2.3:o:siemens:sinamics_g220_firmware:6.4:hf1:*:*:*:*:*:*",
    "cpe:2.3:o:siemens:sinamics_s200_firmware:6.4:*:*:*:*:*:*:*",
    "cpe:2.3:o:siemens:sinamics_s210_firmware:6.4:-:*:*:*:*:*:*",
    "cpe:2.3:o:siemens:sinamics_s210_firmware:6.4:hf1:*:*:*:*:*:*"
  ],
  "cvss_by_source": {
    "cna": 6.9,
    "nvd": 9.8
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "Siemens",
        "product": "SINAMICS G220 V6.4",
        "ranges": [
          "\u003c V6.4 HF2"
        ],
        "fixed_in": [
          "V6.4 HF2"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SINAMICS S200 V6.4",
        "ranges": [
          "\u003c V6.4 HF7"
        ],
        "fixed_in": [
          "V6.4 HF7"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SINAMICS S210 V6.4",
        "ranges": [
          "\u003c V6.4 HF2"
        ],
        "fixed_in": [
          "V6.4 HF2"
        ]
      }
    ],
    "upgrade": [
      "Upgrade SINAMICS G220 V6.4 to V6.4 HF2 or later.",
      "Upgrade SINAMICS S200 V6.4 to V6.4 HF7 or later.",
      "Upgrade SINAMICS S210 V6.4 to V6.4 HF2 or later."
    ]
  },
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}