{
  "id": "CVE-2025-34035",
  "url": "https://poc.griffinguard.io/cve/CVE-2025-34035",
  "published_at": "2025-06-24T01:00:23.862Z",
  "title": "EnGenius EnShare IoT Gigabit Cloud Service Command Injection",
  "vendor": "EnGenius",
  "product": "EnShare IoT Gigabit Cloud Service",
  "cvss": {
    "score": 10,
    "source": "cna",
    "vector": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": {
    "created_at": "2025-08-19T19:27:07Z",
    "first_seen_at": null,
    "days_after_publication": 56.8,
    "source": "nuclei",
    "url": "https://github.com/projectdiscovery/nuclei-templates/blob/main/http/cves/2025/CVE-2025-34035.yaml"
  },
  "poc_repo_count": 0,
  "exploit_count": 1,
  "suspicious_repo_count": 0,
  "edge_device": {
    "category": "Device firmware",
    "confidence": "medium",
    "reason": "hardware or firmware CPE: engeniustech epg5000_firmware"
  },
  "description": "An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise. Exploitation evidence was observed by the Shadowserver Foundation on 2024-12-05 UTC.",
  "cwe": "CWE-78",
  "cpes": [
    "cpe:2.3:o:engeniustech:epg5000_firmware:1.2.0:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:epg5000_firmware:1.3.0:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:epg5000_firmware:1.3.2:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:epg5000_firmware:1.3.3.17:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:epg5000_firmware:1.3.3:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr1200_firmware:1.1.0:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr1200_firmware:1.3.1.34:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr1200_firmware:1.4.1:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr1200_firmware:1.4.3:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr1200_firmware:1.4.5:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr1750_firmware:1.1.0:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr1750_firmware:1.2.2.27:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr1750_firmware:1.3.0:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr1750_firmware:1.3.1.34:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr1750_firmware:1.4.0:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr1750_firmware:1.4.1:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr1750_firmware:1.4.3:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr1750_firmware:1.4.5:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr300_firmware:1.1.0.28:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr300_firmware:1.3.1.42:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr300_firmware:1.4.0:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr300_firmware:1.4.1.28:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr300_firmware:1.4.2:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr300_firmware:1.4.7:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr300_firmware:1.4.9:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr350_firmware:1.1.0.29:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr350_firmware:1.3.1.41:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr350_firmware:1.4.0:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr350_firmware:1.4.11:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr350_firmware:1.4.2:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr350_firmware:1.4.5:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr350_firmware:1.4.9:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr600_firmware:1.1.0.50:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr600_firmware:1.2.1.46:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr600_firmware:1.3.1.63:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr600_firmware:1.4.0.23:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr600_firmware:1.4.11:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr600_firmware:1.4.1:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr600_firmware:1.4.2:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr600_firmware:1.4.3:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr600_firmware:1.4.5:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr600_firmware:1.4.9:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr900_firmware:1.1.0:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr900_firmware:1.2.2.23:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr900_firmware:1.3.0:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr900_firmware:1.3.1.26:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr900_firmware:1.3.5.18:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr900_firmware:1.4.0:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr900_firmware:1.4.3:*:*:*:*:*:*:*",
    "cpe:2.3:o:engeniustech:esr900_firmware:1.4.5:*:*:*:*:*:*:*"
  ],
  "cvss_by_source": {
    "cna": 10,
    "nvd": 9.8
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "EnGenius",
        "product": "EnShare IoT Gigabit Cloud Service",
        "ranges": [
          "\u003c= 1.4.11"
        ],
        "fixed_in": null
      }
    ]
  },
  "exploit_refs": [
    {
      "url": "https://cxsecurity.com/issue/WLB-2017060050",
      "source": "cvelist",
      "title": "",
      "published_at": null,
      "first_seen_at": "2026-11-14T10:26:36.149Z"
    },
    {
      "url": "https://packetstormsecurity.com/files/142792",
      "source": "cvelist",
      "title": "",
      "published_at": null,
      "first_seen_at": "2026-11-14T10:26:36.149Z"
    },
    {
      "url": "https://www.exploit-db.com/exploits/42114",
      "source": "cvelist",
      "title": "",
      "published_at": null,
      "first_seen_at": "2026-11-14T10:26:36.149Z"
    },
    {
      "url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2017-5413.php",
      "source": "cvelist",
      "title": "",
      "published_at": null,
      "first_seen_at": "2026-11-14T10:26:36.149Z"
    },
    {
      "url": "https://github.com/projectdiscovery/nuclei-templates/blob/main/http/cves/2025/CVE-2025-34035.yaml",
      "source": "nuclei",
      "title": "nuclei template: EnGenius EnShare IoT Gigabit Cloud Service 1.4.11 Root Remote Code Execution",
      "published_at": "2025-08-19T19:27:07Z",
      "first_seen_at": "2026-11-14T10:26:36.149Z"
    }
  ],
  "hunt_profile": [],
  "rules": []
}
