  "id": "CVE-2025-30176",
  "url": "https://poc.griffinguard.io/cve/CVE-2025-30176",
  "published_at": "2025-05-13T09:38:39.738Z",
  "vendor": "Siemens",
  "product": "SIMATIC PCS neo V4.1",
  "cvss": {
    "score": 8.7,
    "source": "cna",
    "vector": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": null,
  "description": "A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions \u003c V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions \u003c V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.",
  "cwe": "CWE-125",
  "cpes": [
    "cpe:2.3:a:siemens:simatic_pcs_neo:4.1:*:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:simatic_pcs_neo:5.0:*:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:sinema_remote_connect:-:*:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:totally_integrated_automation_portal:17:*:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:totally_integrated_automation_portal:19:*:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:totally_integrated_automation_portal:20:*:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:user_management_component:*:*:*:*:*:*:*:*"
  ],
  "cvss_by_source": {
    "cna": 8.7
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "Siemens",
        "product": "SIMATIC PCS neo V4.1",
        "ranges": [
          "\u003c *"
        ],
        "fixed_in": [
          "*"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SIMATIC PCS neo V5.0",
        "ranges": [
          "\u003c *"
        ],
        "fixed_in": [
          "*"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SINEC NMS",
        "ranges": [
          "\u003c V4.0"
        ],
        "fixed_in": [
          "V4.0"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "SINEMA Remote Connect",
        "ranges": [
          "\u003c *"
        ],
        "fixed_in": [
          "*"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "Totally Integrated Automation Portal (TIA Portal) V17",
        "ranges": [
          "\u003c *"
        ],
        "fixed_in": [
          "*"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "Totally Integrated Automation Portal (TIA Portal) V18",
        "ranges": [
          "\u003c *"
        ],
        "fixed_in": [
          "*"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "Totally Integrated Automation Portal (TIA Portal) V19",
        "ranges": [
          "\u003c *"
        ],
        "fixed_in": [
          "*"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "Totally Integrated Automation Portal (TIA Portal) V20",
        "ranges": [
          "\u003c *"
        ],
        "fixed_in": [
          "*"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "User Management Component (UMC)",
        "ranges": [
          "\u003c V2.15.1.1"
        ],
        "fixed_in": [
          "V2.15.1.1"
        ]
      }
    ],
    "upgrade": [
      "Upgrade SIMATIC PCS neo V4.1 to * or later.",
      "Upgrade SIMATIC PCS neo V5.0 to * or later.",
      "Upgrade SINEC NMS to V4.0 or later.",
      "Upgrade SINEMA Remote Connect to * or later.",
      "Upgrade Totally Integrated Automation Portal (TIA Portal) V17 to * or later.",
      "Upgrade Totally Integrated Automation Portal (TIA Portal) V18 to * or later.",
      "Upgrade Totally Integrated Automation Portal (TIA Portal) V19 to * or later.",
      "Upgrade Totally Integrated Automation Portal (TIA Portal) V20 to * or later.",
      "Upgrade User Management Component (UMC) to V2.15.1.1 or later."
    ]
  },
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}