  "id": "CVE-2025-27456",
  "url": "https://poc.griffinguard.io/cve/CVE-2025-27456",
  "published_at": "2025-07-03T11:32:21.466Z",
  "title": "CVE-2025-27456",
  "vendor": "Endress+Hauser",
  "product": "Endress+Hauser MEAC300-FNADE4",
  "cvss": {
    "score": 9.8,
    "source": "nvd",
    "vector": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": {
    "category": "Device firmware",
    "confidence": "medium",
    "reason": "hardware or firmware CPE: endress meac300-fnade4_firmware"
  },
  "description": "The SMB server's login mechanism does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it susceptible to brute-force attacks.",
  "cwe": "CWE-307",
  "cpes": [
    "cpe:2.3:o:endress:meac300-fnade4_firmware:*:*:*:*:*:*:*:*"
  ],
  "cvss_by_source": {
    "cna": 7.5,
    "nvd": 9.8
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "Endress+Hauser",
        "product": "Endress+Hauser MEAC300-FNADE4",
        "ranges": [
          "vers:all/*"
        ],
        "fixed_in": null
      }
    ],
    "workarounds": [
      "Please make sure that you apply general security practices when operating the MEAC300-FNADE4. The following General Security Practices could mitigate the associated security risk."
    ],
    "references": [
      {
        "kind": "Vendor advisory",
        "url": "https://sick.com/psirt"
      },
      {
        "kind": "Vendor advisory",
        "url": "https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0008.pdf"
      }
    ]
  },
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}