  "id": "CVE-2025-23401",
  "url": "https://poc.griffinguard.io/cve/CVE-2025-23401",
  "published_at": "2025-03-11T09:48:16.806Z",
  "vendor": "Siemens",
  "product": "Teamcenter Visualization V14.3",
  "cvss": {
    "score": 7.8,
    "source": "cna",
    "vector": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": null,
  "description": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process.",
  "cwe": "CWE-125",
  "cpes": [
    "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
    "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*"
  ],
  "cvss_by_source": {
    "cna": 7.8
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "Siemens",
        "product": "Teamcenter Visualization V14.3",
        "ranges": [
          "\u003c V14.3.0.13"
        ],
        "fixed_in": [
          "V14.3.0.13"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "Teamcenter Visualization V2312",
        "ranges": [
          "\u003c V2312.0009"
        ],
        "fixed_in": [
          "V2312.0009"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "Teamcenter Visualization V2406",
        "ranges": [
          "\u003c V2406.0007"
        ],
        "fixed_in": [
          "V2406.0007"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "Teamcenter Visualization V2412",
        "ranges": [
          "\u003c V2412.0002"
        ],
        "fixed_in": [
          "V2412.0002"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "Tecnomatix Plant Simulation V2302",
        "ranges": [
          "\u003c V2302.0021"
        ],
        "fixed_in": [
          "V2302.0021"
        ]
      },
      {
        "vendor": "Siemens",
        "product": "Tecnomatix Plant Simulation V2404",
        "ranges": [
          "\u003c V2404.0010"
        ],
        "fixed_in": [
          "V2404.0010"
        ]
      }
    ],
    "upgrade": [
      "Upgrade Teamcenter Visualization V14.3 to V14.3.0.13 or later.",
      "Upgrade Teamcenter Visualization V2312 to V2312.0009 or later.",
      "Upgrade Teamcenter Visualization V2406 to V2406.0007 or later.",
      "Upgrade Teamcenter Visualization V2412 to V2412.0002 or later.",
      "Upgrade Tecnomatix Plant Simulation V2302 to V2302.0021 or later.",
      "Upgrade Tecnomatix Plant Simulation V2404 to V2404.0010 or later."
    ]
  },
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}