  "id": "CVE-2025-0867",
  "url": "https://poc.griffinguard.io/cve/CVE-2025-0867",
  "published_at": "2025-02-14T12:37:09.25Z",
  "title": "Privilege Escalation in MEAC300",
  "vendor": "SICK AG",
  "product": "SICK MEAC300",
  "cvss": {
    "score": 9.9,
    "source": "cna",
    "vector": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H"
  },
  "kev": {
    "in_kev": false,
    "added_at": null,
    "days_after_publication": null
  },
  "first_poc": null,
  "poc_repo_count": 0,
  "exploit_count": 0,
  "suspicious_repo_count": 0,
  "edge_device": null,
  "description": "The standard user uses the run as function to start the MEAC applications with administrative privileges. To ensure that the system can startup on its own, the credentials of the administrator were stored. Consequently, the EPC2 user can execute any command with administrative privileges. This allows a privilege escalation to the administrative level.",
  "cwe": "CWE-522",
  "cvss_by_source": {
    "cna": 9.9
  },
  "repos": [],
  "remediation": {
    "affected": [
      {
        "vendor": "SICK AG",
        "product": "SICK MEAC300",
        "ranges": [
          "\u003c 4.0.54.21"
        ],
        "fixed_in": [
          "4.0.54.21"
        ]
      }
    ],
    "solutions": [
      "Users are strongly recommended to upgrade to the latest release of the MEAC300 (\u003e=4.0.54.21) that includes a patch for the vulnerability."
    ],
    "upgrade": [
      "Upgrade SICK MEAC300 to 4.0.54.21 or later."
    ],
    "references": [
      {
        "kind": "Vendor advisory",
        "url": "https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0001.pdf"
      },
      {
        "kind": "Vendor advisory",
        "url": "https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0001.json"
      }
    ]
  },
  "exploit_refs": [],
  "hunt_profile": [],
  "rules": []
}